• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.9.2001.tde-27082012-161157
Document
Author
Full name
Andréia Peraro do Nascimento
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2001
Supervisor
Committee
Kedor, Erika Rosa Maria (President)
Araujo, Magali Benjamin de
Santoro, Maria Inês Rocha Miritello
Title in Portuguese
Estabilidade física e metodologia analítica para formulações farmacêuticas contendo cetoconazol
Keywords in Portuguese
Análise de medicamentos e cosméticos
Antifúngicos (Farmacologia)
Cetoconazol
Controle de qualidade
Cromatografia líquida
Espectrofotometria derivada
Medicamento
Química farmacêutica
Abstract in Portuguese
O cetoconazol é um derivado imidazólico com atividade antifúngica, empregado no tratamento de grande variedade de infecções cutâneas. O objetivo deste trabalho foi a padronização e a validação dos métodos analíticos empregando-se a espectrofotometria no ultravioleta ( UV ) por derivada de primeira ordem e a cromatografia líquida de alta eficiência (CLAE) para a determinação do cetoconazol em formulações farmacêuticas sob a forma de creme obtidas no comércio e formuladas em laboratório. O estudo da estabilidade física das formulações obtidas em laboratório foi realizado após o armazenamento sob diferentes condições de tempo, temperatura e umidade. O método espectrofotométrico no UV por derivada de primeira ordem foi padronizado a 257nm , no intervalo de concentração de 5,0 a 30,0 µg/mL em metanol. O coeficiente de correlação linear foi de 0,9997, o percentual de recuperação foi de 100,24%. A média do desvio padrão relativo foi de 0,56% para a amostra simulada e 0,41% para a amostra comercial. A determinação de cetoconazol por CLAE foi realizada empregando-se uma coluna LiChrospher® 100 RP- 18 ( 5µm ) e fase móvel constituída por uma mistura de trietilamina em metanol( 1:500 ) e solução de acetato de amônio em água (1:200 ) na proporção de 75 : 25 v/v, com vazão de 1,0 mL/min e detecção no UV a 225 nm. O terconazol foi utilizado como padrão interno. O coeficiente de correlação linear foi de 0,9981, o percentual de recuperação foi de 100,88%, a média do desvio padrão foi de 2,13% para a amostra simulada e 1,25% para a amostra comercial. A amostra simulada apresentou comportamento pseudoplástico e tixotropia em decorrência das medidas reológicas obtidas experimentalmente.
Title in English
Study the stability and analytical methods to determine ketoconazole in dosage forms preparations
Keywords in English
Antifungal (Pharmacology)
Derivative spectrophotometry
Drugs
Ketoconazole
Liquid chromatography
Pharmaceutical chemistry
Quality control
Abstract in English
Ketoconazole is an imidazole antifungal agent used in the treatment of great variety of skin infectious diseases. The aim of this research was the standardization and the validation of two analytical methods, first derivative ultraviolet ( UV ) spectrophotometry and high performance liquid chromatography( HPLC ) to determine ketoconazole in commercial and simulated cream dosage forms preparations. The validated methods were used to study the stability of the simulated cream after storage under high temperatures and high percentage of humidity. First derivative UV spectrophotometry was standardized at 257 nm, in a range of concentration from 5.0 to 30.0 µg/mL in methanol. The coefficient of correlation was 0.9997 and the recovery average was 100.24%. The average relative standard deviation ( RSD ) was 0.56% for simulated preparation and 0.41 % for commercial preparation. The determination of ketoconazole by HPLC was performed using a LiChrospher® 100 RP-18(5µm ) column, a mobile phase consisting of triethylamine in methanol (1:500) and ammonium acetate solution in water(1:200 ) 75:25 ( v/v ), a flow rate of 1.0 mL/min and UV detection at 225nm. Terconazole was used as internal standard. The coefficient of correlation was 0.9981, the recovery average was 100.88%, the average relative standard deviation ( RSD ) was 2.13% for the simulated preparations and 1.25% for the commercial preparations. The rheological measurements showed that the simulated preparation presented pseudoplastic and thixotropic behavior.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2012-08-27
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.