• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.9.2017.tde-26102017-114152
Document
Auteur
Nom complet
Laíse de Oliveira Andrade
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2017
Directeur
Jury
Pinto, Terezinha de Jesus Andreoli (Président)
Bugno, Adriana
Oliveira, Débora Cristina de
Torres, Ieda Maria Sapateiro
Titre en portugais
Métodos rápidos para identificação microbiana aplicados ao monitoramento ambiental de salas limpas: ênfase na tecnologia MALDI-TOF
Mots-clés en portugais
Espectrometria de massas baseada na tecnologia MALDI-TOF
Identificação bacteriana
Métodos microbiológicos rápidos
Monitoramento ambiental
Sala limpa
Resumé en portugais
A espectrometria de massas baseada na tecnologia MALDI-TOF (do inglês, matrix-assisted laser desorption ionization-time of flight) (MALDI-TOF MS) tem sido cada vez mais incorporada à rotina de identificações microbiológicas nos laboratórios farmacêuticos de controle de qualidade, principalmente para as atividades do Programa de Monitoramento Ambiental de Salas Limpas. Isso porque o longo tempo necessário para a obtenção dos resultados por meio de métodos convencionais tem incentivado a procura por técnicas que permitam métodos rápidos. O objetivo deste trabalho foi avaliar a adequação da técnica MALDI-TOF MS para a identificação de bactérias isoladas do ambiente de salas limpas utilizadas em algumas etapas da produção de uma vacina viral. Treze espécies bacterianas conhecidas, normalmente isoladas das salas limpas estudadas, e cinco cepas ATCC foram identificadas pela técnica MALDI-TOF MS e por uma técnica bioquímica (BBL Crystal®). O desempenho da técnica MALDI-TOF MS foi superior ao da técnica bioquímica na identificação correta das espécies bacterianas (88,89% e 38,89%, respectivamente) e produziu menos identificações não confiáveis (5,55% e 22,22%, respectivamente). Os resultados evidenciaram que a técnica MALDI-TOF MS pode ser implementada para identificação rotineira de bactérias em um laboratório de controle de qualidade farmacêutico. Entretanto, a dependência de bases de dados exige estudos adicionais de isolados não identificados e, se apropriado, a adição destes a uma base de dados interna. O aperfeiçoamento de métodos de identificação microbiana é muito relevante no contexto de salas limpas, pois permitem ações corretivas e proativas essenciais para garantir a segurança microbiológica do processamento asséptico.
Titre en anglais
Rapid methods for microbial identification applied to clean room environmental monitoring: emphasis on MALDI-TOF technology
Mots-clés en anglais
Bacterial identification
Environmental monitoring
Matrix-assisted laser desorption ionization-time of flight mass spectrometry
Pharmaceutical clean room
Rapid microbiological methods
Resumé en anglais
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been increasingly introduced in routine microbiological identifications of pharmaceutical quality control laboratories, mainly for the activities of the Environmental Monitoring Program of Clean Rooms. The long time needed to obtain the results through conventional methods has stimulated the search for techniques that allow rapid methods, as MALDI-TOF MS. Thus, the objective of this work was to evaluate the suitability of the MALDI-TOF MS technique for the identification of bacteria isolated from the environment of clean rooms used in some stages of the production of a viral vaccine. Thirteen bacterial species commonly isolated from clean rooms studied and five strains ATCC were identified by MALDI-TOF MS technique and by a biochemical technique (BBL Crystal® System). Performance of MALDI-TOF MS was better than biochemical technique for correct species identifications (88.89% and 38.89%, respectively) and produced fewer unreliable identifications (5.55% and 22.22%, respectively). MALDI-TOF MS can be implemented for routine identification of bacteria in a pharmaceutical quality control laboratory. However, as a database-dependent system, maybe some isolated not identified by this technique must be additionally studied and, if appropriate, added to an in-house database.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-10-31
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.