Desenvolvimento de métodos para análise do besilato de anlodipino para inclusão da monografia na farmacopéia brasileira
Palabras clave en portugués
Besilato de anlodipino
CLAE
Controle de qualidade
Controle físico-químico de qualidade dos fármacos
Cromatografia líquida de alta Eeficiência (Aplicações)
Espectrofotometria (Aplicações)
Espectrometria
Fármacos (Determinação;Características)
Validação
Resumen en portugués
O objetivo desta pesquisa foi desenvolver e validar métodos analíticos para o fármaco besilato de anlodipino (ABC) em comprimidos. O método espectrofotométrico no ultra violeta e o método por cromatografia líquida de alta eficiência (CLAE) desenvolvidos foram considerados simples, exatos e precisos. Foram analisadas amostras contendo 5 mg,10 mg e uma amostra formulada de 5mg de ABC/comprimido. Para o método espectrofotométrico, a primeira diluição das amostras foi feita em metanol e as subseqüentes em água. A leitura foi efetuada a 364,4 nm. A linearidade para ABC foi estabelecida na faixa de 41,0-61,0 mg/mL e o coeficiente de correlação foi R= 0,9996. O limite de detecção e o de quantificação foram respectivamente 0,54 e 1,8 mcg/mL. A exatidão e a precisão foram 98,99% e 0,37%, respectivamente. Nas análises por cromatografia líquida de alta eficiência (CLAE), foram utilizadas as seguintes condições: coluna LiChrospher ® 100 RP-18 Merck ® (250 mm x 4,6 mm, 5µm), fase móvel constituída por metanol: água: (35:65) com 1% de TEA e pH ajustado para 5.0 com ácido fosfórico; fluxo de 1,0 mL/min; detecção UV a 238 nm e temperatura de 22 ±1°C.Tempo de retenção (RT) ABC foi de 3,7 min. Foi obtida linearidade no intervalo de 50 a 350 mcg/mL e coeficiente de correlação = 0,9999. O limite de detecção e o de quantificação foram respectivamente de 2,26 mcg/mL e 7,52 mcg/mL. A exatidão foi de 100,18% e a precisão foi de 0,37% para a CLAE. Ambos os métodos podem ser usados na rotina de análise para o controle de qualidade de comprimidos contendo ABC.
Título en inglés
Development of methods for the analysis of amlodipine besylate for inclusion of the monograph in the Brazilian Pharmacopoeia
Palabras clave en inglés
Amlodipine besilate
High Performance Liquid Chromatography (Applications)
HPLC
Physicochemical control of drug quality
Quality control. Drugs (Determination; Characteristics)
Spectrophotometric
Spectrophotometry (Applications)
Validation
Resumen en inglés
The objective of this research was to develop and validate analytical methods for the amlodipine besylate (ABC) determination in tablets. Simple, accurate and precise spectrophotometric and HPLC methods were validate for ABC determination in samples containing 5.0 and 10.0 mg of ABC / tablet. For the spectrophotometric method, the first dilutions of samples were made in methanol and the consecutive in distilled water. Determination was made at 364.4 nm. Linearity was in the range of 41.0-61.0 µg/mL and r= 0.9996. The detection and quantitation limits were respectively, 0.54 µg/mL and 1.80 µg/mL. Accuracy and precision were respectively, 98.99% and 0.37%. For HPLC analysis, the following conditions were used: a LiChrospher ® 100 RP-18 Merck® (250 mm x 4,6 mm, 5µm) column; methanol: water with 1% of triethylamine adjusted to pH 5.0 with phosphoric acid (35:65), as mobile phase; a flow rate of 1.0 mL /min; UV detection at 238 nm and temperature of 22 ±1 °C . Retention time was 3.7 min. Linearity was in the range of 50.0 - 350.0 µg/mL and r = 0.9999. The detection and quantitation limits were respectively, 2.26 µg/mL and 7.52 µg/mL. Accuracy and precision were respectively, 100.18% and 0.37%. Both methods can be used in routine analysis for quality control of tablets containing ABC.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-01-26
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.