• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.9.1998.tde-23062008-165853
Document
Auteur
Nom complet
Cristina Helena dos Reis Serra
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 1998
Directeur
Jury
Storpirtis, Sílvia (Président)
Bentley, Maria Vitória Lopes Badra
Consiglieri, Vladi Olga
Gai, Maria Nella
Lanchote, Vera Lúcia
Titre en portugais
Avaliação biofarmacotécnica de comprimidos contendo cefalexina: cinética de dissolução e bioequivalência
Mots-clés en portugais
Bioequivalência
Biofarmacotécnica
Cefalexina
Cinética de dissolução
Comprimidos
Resumé en portugais
A cefalexina é um antibiótico semi-sintético, derivado das cefalosporinas, que exibe amplo espectro de ação, sendo largamente empregado por via oral. No Brasil é comercializado na forma de comprimido revestido, por cinco laboratórios farmacêuticos diferentes. No presente estudo foram avaliados, do ponto de vista biofarmacotécnico, 2 especialidades farmacêuticas (A e B), sob a forma de comprimidos revestidos, contendo 500 mg de cefalexina, disponíveis no mercado nacional. A análise in vitro foi realizada para dois lotes (1 e 2) de cada produto (A e B), através de ensaios físicos e físico-químicos (peso médio, dureza, umidade, teor de cefalexina, teste e perfil de dissolução), com a finalidade de verificar sua conformidade com especificações estabelecidas pelos compêndios oficiais. Estudos de cinética de dissolução foram empregados para avaliação mais precisa quanto às características biofarmacotécnicas in vitro das respectivas formulações. Os estudos de bioequivalência entre os produtos A e B (lote 2) empregaram delineamento experimental cruzado aleatório, em dois períodos, utilizando-se 24 voluntários. Os parâmetros farmacocinéticos empregados nesta avaliação foram obtidos a partir de dados de excreção urinária da cefalexina, sendo sua concentração na urina determinada por cromatografia líquida de alta eficiência, através de metodologia desenvolvida e validada no presente estudo. A bioequivalência entre os produtos foi determinada a partir da análise estatística (ANOVA) dos seguintes dados: quantidade de cefalexina acumulada excretada na urina (Du acumulado); quantidade total de cefalexina excretada na urina no tempo infinito (Du); velocidade máxima de excreção urinária ([Ddu/dt]max). Os resultados das análises físicas e físico-químicas indicaram que ambos os produtos estudados apresentaram-se dentro das especificações farmacopéicas. Na avaliação da bioequivalência entre os mesmos, obtiveram-se intervalos de confiança dentro dos limites estabelecidos internacionalmente (80 a 125%), para todos os parâmetros avaliados, comprovando, desta forma, que os produtos A e B são bioequivalentes e, portanto, intercambiáveis.
Titre en anglais
Biopharmaceutical evaluation of cephalexin tablets : dissolution kinetic and bioequivalence
Mots-clés en anglais
Bioequivalence
Biopharmaceutical
Cephalexin
Dissolution kinetics
Tablets
Resumé en anglais
Cephalexin is a semi-synthetic cephalosporin-derived antibiotic which has an extensive action spectrum, widely used by oral administration. In Brazil, where it is largely marketed, in a tablet coated way, five differents brands can be found. The goal of this study was to evaluate from the biopharmaceutic point of view two cephalexin 500 mg tablet brands (A and B) availables in brazilian market. In order to check its accordance with official pharmacopeial specifications, two lots (1 and 2) of each brand (A and B) were analysed in vitro through physical and physical-chemical assays in vitro tests (average weight, hardness, wet, cephalexin content, dissolution test). Both formulations were also submitted to dissolution kinetics studies to reach an accurate evaluation of their in vitro biopharmaceutics features. The bioequivalence studies between A and B brands (Iot 2) was based on an open randomized two period cross over design with twenty-four male and female healthy volunteers. Pharmacokinetics parameters used in this evaluation were obtained from cephalexin urinary excretion data; to assess urine cephalexin concentrations a high performance liquid chromatographic assay developed and validated in this study was used. Bioequivalence was confirmed using a multiway ANOVA and when the 90 % confidence interval for accumulated cephalexin amount excreted in urine (Du accumulated); total amount of cephalexín excreted in urine (Du ) and maximum rate of urinary excretion ([dDu/dt]max), fell within the interval 80-125 %.No discrepancies between both cephalexin brands in physical-chemycal tests were found. Confidence intervals for pharmacokinetics parameters were inside the bioequivalence limits according with the international atandars (80-125%), demonstrating that A and B formulations can be considered bioequivalent and therefore interchangeable.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2008-06-25
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.