• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.9.1998.tde-23062008-165853
Document
Author
Full name
Cristina Helena dos Reis Serra
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 1998
Supervisor
Committee
Storpirtis, Sílvia (President)
Bentley, Maria Vitória Lopes Badra
Consiglieri, Vladi Olga
Gai, Maria Nella
Lanchote, Vera Lúcia
Title in Portuguese
Avaliação biofarmacotécnica de comprimidos contendo cefalexina: cinética de dissolução e bioequivalência
Keywords in Portuguese
Bioequivalência
Biofarmacotécnica
Cefalexina
Cinética de dissolução
Comprimidos
Abstract in Portuguese
A cefalexina é um antibiótico semi-sintético, derivado das cefalosporinas, que exibe amplo espectro de ação, sendo largamente empregado por via oral. No Brasil é comercializado na forma de comprimido revestido, por cinco laboratórios farmacêuticos diferentes. No presente estudo foram avaliados, do ponto de vista biofarmacotécnico, 2 especialidades farmacêuticas (A e B), sob a forma de comprimidos revestidos, contendo 500 mg de cefalexina, disponíveis no mercado nacional. A análise in vitro foi realizada para dois lotes (1 e 2) de cada produto (A e B), através de ensaios físicos e físico-químicos (peso médio, dureza, umidade, teor de cefalexina, teste e perfil de dissolução), com a finalidade de verificar sua conformidade com especificações estabelecidas pelos compêndios oficiais. Estudos de cinética de dissolução foram empregados para avaliação mais precisa quanto às características biofarmacotécnicas in vitro das respectivas formulações. Os estudos de bioequivalência entre os produtos A e B (lote 2) empregaram delineamento experimental cruzado aleatório, em dois períodos, utilizando-se 24 voluntários. Os parâmetros farmacocinéticos empregados nesta avaliação foram obtidos a partir de dados de excreção urinária da cefalexina, sendo sua concentração na urina determinada por cromatografia líquida de alta eficiência, através de metodologia desenvolvida e validada no presente estudo. A bioequivalência entre os produtos foi determinada a partir da análise estatística (ANOVA) dos seguintes dados: quantidade de cefalexina acumulada excretada na urina (Du acumulado); quantidade total de cefalexina excretada na urina no tempo infinito (Du); velocidade máxima de excreção urinária ([Ddu/dt]max). Os resultados das análises físicas e físico-químicas indicaram que ambos os produtos estudados apresentaram-se dentro das especificações farmacopéicas. Na avaliação da bioequivalência entre os mesmos, obtiveram-se intervalos de confiança dentro dos limites estabelecidos internacionalmente (80 a 125%), para todos os parâmetros avaliados, comprovando, desta forma, que os produtos A e B são bioequivalentes e, portanto, intercambiáveis.
Title in English
Biopharmaceutical evaluation of cephalexin tablets : dissolution kinetic and bioequivalence
Keywords in English
Bioequivalence
Biopharmaceutical
Cephalexin
Dissolution kinetics
Tablets
Abstract in English
Cephalexin is a semi-synthetic cephalosporin-derived antibiotic which has an extensive action spectrum, widely used by oral administration. In Brazil, where it is largely marketed, in a tablet coated way, five differents brands can be found. The goal of this study was to evaluate from the biopharmaceutic point of view two cephalexin 500 mg tablet brands (A and B) availables in brazilian market. In order to check its accordance with official pharmacopeial specifications, two lots (1 and 2) of each brand (A and B) were analysed in vitro through physical and physical-chemical assays in vitro tests (average weight, hardness, wet, cephalexin content, dissolution test). Both formulations were also submitted to dissolution kinetics studies to reach an accurate evaluation of their in vitro biopharmaceutics features. The bioequivalence studies between A and B brands (Iot 2) was based on an open randomized two period cross over design with twenty-four male and female healthy volunteers. Pharmacokinetics parameters used in this evaluation were obtained from cephalexin urinary excretion data; to assess urine cephalexin concentrations a high performance liquid chromatographic assay developed and validated in this study was used. Bioequivalence was confirmed using a multiway ANOVA and when the 90 % confidence interval for accumulated cephalexin amount excreted in urine (Du accumulated); total amount of cephalexín excreted in urine (Du ) and maximum rate of urinary excretion ([dDu/dt]max), fell within the interval 80-125 %.No discrepancies between both cephalexin brands in physical-chemycal tests were found. Confidence intervals for pharmacokinetics parameters were inside the bioequivalence limits according with the international atandars (80-125%), demonstrating that A and B formulations can be considered bioequivalent and therefore interchangeable.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2008-06-25
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.