Título en portugués
Desafios emergentes na segurança e qualidade microbiológica da água para uso farmacêutico
Palabras clave en portugués
Água purificada
Citometria de fluxo
Métodos microbiológicos rápidos
Resumen en portugués
A água é, sem dúvida, a matéria-prima de maior volume empregada, considerando de forma global, na produção farmacêutica. Pode ser usada direta ou indiretamente, com profundo potencial de impacto na qualidade do produto e na segurança do paciente. Consiste em meio de crescimento que, embora não rico, apresenta variações em suas características microbianas. Sendo assim, os métodos tradicionais utilizados em sua análise, apesar de simples, exigem vários dias para obtenção de resultados e muitas vezes não são sensíveis o suficiente para recuperar microrganismos em determinados estados fisiológicos, como por exemplo, biofilmes ou em estado viável não cultivável. Em virtude disso, o presente trabalho foi elaborado com intuito de desenvolver pesquisas para inovar no controle de qualidade microbiológico da água utilizada para fins farmacêuticos e, além de agregar novas técnicas, visa que os produtos farmacêuticos estejam disponíveis no mercado de modo rápido, seguro, eficaz e com a qualidade desejada. Desta forma, o objetivo do presente trabalho foi avaliar o potencial das tecnologias alternativas, em específico a citometria de fluxo, no monitoramento microbiano da água purificada, de forma a assegurar a manutenção de baixo risco de falha microbiana. O estudo foi conduzido em três etapas: a primeira etapa foi denominada de prova de conceito e teve por objetivo avaliar se existia alguma correlação entre os resultados obtidos com o método alternativo com aqueles obtidos com o método tradicional; a segunda etapa foi a validação da metodologia alternativa, etapa na qual foram avaliados todos os parâmetros de validação exigidos pelas principais normas e compêndios farmacêuticos; a terceira e última etapa foi denominada de equivalência, etapa na qual foi demonstrada a equivalência entre o método alternativo e os métodos farmacopeicos quando desafiados com amostras de água purificada coletadas de reservatórios da Faculdade de Ciências Farmacêuticas (FCF/USP). Os resultados obtidos no presente estudo demonstraram que a citometria de fluxo é não só uma opção válida em relação ao método tradicional por semeadura em profundidade como também oferece como principal vantagem a possibilidade de se ter resultados em tempo real, possibilitando efetuar qualquer correção no processo produtivo a tempo.
Título en inglés
Emerging challenges in the security and microbiological quality of water for pharmaceutical purposes
Palabras clave en inglés
Flow citometry
Purified water
Rapid microbiological methods
Resumen en inglés
Water certainly is the most used raw material used in pharmaceutical industry, considering volume of material and manufacturing process. It may be used either directly or indirectly, causing a considerable impact on product quality and patient safety. It may be considered a poor culture media that presents variable microbiologic characteristics. Even though the traditional microbiological methods used for water evaluation are simple, data obtainment requires several days. In addition, these methods are unable to recover microorganisms from determined physiological conditions, such as those observed in biofilms or in a viable but non-culturable state. Therefore, the present work aimed to research innovative methods for microbiologic quality control of water for pharmaceutical use. The new techniques intend to provide pharmaceutical product to market more rapidly, while maintaining its safety and quality. Specifically, the objective of this work was to evaluate alternative technologies, namely flow cytometry, and their application on microbiological assessment of purified water ensuring the low risk of microbiological fail. This study was conducted in three steps: the first, named as proof of concept, aimed to determine whether occurred any correlation between results obtained from traditional methods and results obtained from alternative method. Validation of alternative method was performed in the second step. This step was executed considering all validation parameters required for main pharmaceuticals norms and compendia. The last step was named equivalency, in which was showed the equivalence between traditional and alternative methods when challenged against purified water sampled from School of Pharmaceutical Sciences (FCF/USP) reservoirs. Results showed that flow citometry is equivalent to traditional methods and was also able to provide real-time evaluation, which enables to adjust the manufacturing process as soon as a deviation is detected.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-02-06
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.