• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.9.2005.tde-18092007-111223
Document
Auteur
Nom complet
Eunice Emiko Mori Koono
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2005
Directeur
Jury
Porta, Valentina (Président)
Costa, Maria Teresa Zulini da
Ribeiro, Eliane
Titre en portugais
Avaliação de bioequivalência de comprimidos contendo 500 mg de tinidazol
Mots-clés en portugais
Bioequivalência
Cromatografia líquida de alta eficiência
Metronidazol
Tinidazol
Resumé en portugais
Tinidazol, 1-[2-(ethylsulphonyl)ethyl]-2-methyl-5-nitroimidazole, é um membro da classe dos nitroimidazóis que apresenta atividade amebicida, giardicida, tricomonicida e anaeróbica. O objetivo deste estudo foi avaliar a bioequivalência de duas marcas comerciais de comprimidos contendo 500 mg de tinidazol em voluntários sadios. O ensaio de bioequivalência entre o produto teste (Amplium® - FARMASA) e o produto referência (Pletil® - Pharmacia do Brasil Ltda) foi do tipo randomizado, cruzado e aberto. O medicamento foi administrado em dose única de 500 mg de tinidazol a 24 voluntários sadios. Amostras de sangue foram coletadas até 72 horas após a administração e analisadas através de método de cromatografia líquida de alta eficiência validado com detecção UV. As curvas médias de decaimento plasmatico obtidas para o produto teste (Amplium® - FARMASA) e para o produto referência (Pletil® - Pharmacia do Brasil Ltda) foram semelhantes, da mesma forma que os parâmetros farmacocinéticos Cmax (referência: 11,34 µg/mL; teste: 11,11 µg/mL), t (referência: 1,67 h; teste: 1,71 h), AUC0-t (referência: 201,92 µgxh/mL; teste: 198,15 µgxh/mL), AUC0-∞ (referência: 208,25 µg/mL; teste: 203,80 µgxh/mL) e t(½)el (referência = 14,05 h; teste = 13,91 h). A análise multivariada realizada através da análise de variância (ANOVA), para avaliação dos efeitos produto, grupo e período, revelou a ausência destes efeitos no estudo, indicando que o delineamento do estudo foi apropriado. Os valores do intervalo de confiança 90% para a razão de Cmax (93.9 % - 102.6 %), AUC0-t (94.9 % - 101.1 %) e AUC0-∞ (94.6 % -100.8 %) encontram-se entre 80 - 125 %, intervalo proposto pelo FDA e ANVISA. A comparação estatística dos parâmetros AUCo-t , AUC0-∞ e Cmax indicam claramente não haver diferença significativa entre os dois produtos contendo 500 mg de tinidazol. Baseado nos resultados farmacocinéticos e estatísticos deste, pode-se concluir que os dois produtos são bioequivalentes e podem ser considerados intercambiáveis na terapêutica.
Titre en anglais
Bioequivalence evaluation of tinidazole 500 mg tablets
Mots-clés en anglais
Bioequivalence
High-performance liquid chromatography
Metronidazole
Tinidazole
Resumé en anglais
Tinidazole, 1-[2-(ethylsulphonyl)ethyl]-2-methyl-5-nitroimidazole, is a member of the 5-nitroimidazole class of antimicrobial agents with amoebicidal, giardicidal, trichomonicidal and anaerobic activity. The purpose of this study was to evaluate the bioequivalence of two brands of tinidazole 500mg tablets in healthy human volunteers. The procedure of bioequivalence between the test product (Amplium® - FARMASA) and reference product (Pletil® - Pharmacia do Brasil Ltda) was a randomized, crossover and open study. The medication was administered in a single dose of 500 mg of tinidazole to 24 healthy volunteers. Blood samples were collected until 72 hours after administration and analised using a validated high-performance liquid chromatographic method with UV detection. The average plasmatic decay curves obtained for the test product (Amplium® - FARMASA) and reference product (Pletil® - Pharmacia do Brasil Ltda) were similar, in the same way as were the pharmacokinetic parameters Cmax (reference: 11.34 µg/mL; test: 11.11 µg/mL), tmax (reference: 1.67 h; test: 1.71 h), AUC0-t (reference: 201.92 µgxh/mL; test: 198.15 µgxh/mL), AUC0-∞ (reference: 208.25 µg/mL; test: 203.80 µgxh/mL) and t(½)el (reference = 14.05 hours, test = 13.91 hours). The multivariate analysis accomplished through analysis of variance (ANOVA), for assessment of product, group and period effects, revealed the absence of any of these effects in the present study, indicating that the crossover design was properly performed. j The 90% confidence intervals for the ratio of Cmax (93.9 % - 102.6 %), AUC0-t (94.9 % - 101.1 %) and AUC0-∞ (94.6 % - 100.8 %) values for the test and reference products are within the 80 - 125 % interval proposed by FDA and ANVISA. Statistical comparison of AUC0-t , AUC0-∞ and Cmax clearly indicated no significant difference between the two brands of tinidazole 500 mg tablets. Based on the pharmacokinetic and statistical results of this study, we can conclude that the two products are bioequivalent, and can be considered interchangeable in medical practice.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
EuniceEmiko.pdf (3.48 Mbytes)
Date de Publication
2007-09-24
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.