Disertación de Maestría
DOI
https://doi.org/10.11606/D.9.2005.tde-18092007-111223
Documento
Autor
Nombre completo
Eunice Emiko Mori Koono
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2005
Director
Tribunal
Porta, Valentina (Presidente)
Costa, Maria Teresa Zulini da
Ribeiro, Eliane
Título en portugués
Avaliação de bioequivalência de comprimidos contendo 500 mg de tinidazol
Palabras clave en portugués
Bioequivalência
Cromatografia líquida de alta eficiência
Metronidazol
Tinidazol
Resumen en portugués
Tinidazol, 1-[2-(ethylsulphonyl)ethyl]-2-methyl-5-nitroimidazole, é um membro da classe dos nitroimidazóis que apresenta atividade amebicida, giardicida, tricomonicida e anaeróbica. O objetivo deste estudo foi avaliar a bioequivalência de duas marcas comerciais de comprimidos contendo 500 mg de tinidazol em voluntários sadios. O ensaio de bioequivalência entre o produto teste (Amplium® - FARMASA) e o produto referência (Pletil® - Pharmacia do Brasil Ltda) foi do tipo randomizado, cruzado e aberto. O medicamento foi administrado em dose única de 500 mg de tinidazol a 24 voluntários sadios. Amostras de sangue foram coletadas até 72 horas após a administração e analisadas através de método de cromatografia líquida de alta eficiência validado com detecção UV. As curvas médias de decaimento plasmatico obtidas para o produto teste (Amplium® - FARMASA) e para o produto referência (Pletil® - Pharmacia do Brasil Ltda) foram semelhantes, da mesma forma que os parâmetros farmacocinéticos Cmax (referência: 11,34 µg/mL; teste: 11,11 µg/mL), t (referência: 1,67 h; teste: 1,71 h), AUC0-t (referência: 201,92 µgxh/mL; teste: 198,15 µgxh/mL), AUC0-∞ (referência: 208,25 µg/mL; teste: 203,80 µgxh/mL) e t(½)el (referência = 14,05 h; teste = 13,91 h). A análise multivariada realizada através da análise de variância (ANOVA), para avaliação dos efeitos produto, grupo e período, revelou a ausência destes efeitos no estudo, indicando que o delineamento do estudo foi apropriado. Os valores do intervalo de confiança 90% para a razão de Cmax (93.9 % - 102.6 %), AUC0-t (94.9 % - 101.1 %) e AUC0-∞ (94.6 % -100.8 %) encontram-se entre 80 - 125 %, intervalo proposto pelo FDA e ANVISA. A comparação estatística dos parâmetros AUCo-t , AUC0-∞ e Cmax indicam claramente não haver diferença significativa entre os dois produtos contendo 500 mg de tinidazol. Baseado nos resultados farmacocinéticos e estatísticos deste, pode-se concluir que os dois produtos são bioequivalentes e podem ser considerados intercambiáveis na terapêutica.
Título en inglés
Bioequivalence evaluation of tinidazole 500 mg tablets
Palabras clave en inglés
Bioequivalence
High-performance liquid chromatography
Metronidazole
Tinidazole
Resumen en inglés
Tinidazole, 1-[2-(ethylsulphonyl)ethyl]-2-methyl-5-nitroimidazole, is a member of the 5-nitroimidazole class of antimicrobial agents with amoebicidal, giardicidal, trichomonicidal and anaerobic activity. The purpose of this study was to evaluate the bioequivalence of two brands of tinidazole 500mg tablets in healthy human volunteers. The procedure of bioequivalence between the test product (Amplium® - FARMASA) and reference product (Pletil® - Pharmacia do Brasil Ltda) was a randomized, crossover and open study. The medication was administered in a single dose of 500 mg of tinidazole to 24 healthy volunteers. Blood samples were collected until 72 hours after administration and analised using a validated high-performance liquid chromatographic method with UV detection. The average plasmatic decay curves obtained for the test product (Amplium® - FARMASA) and reference product (Pletil® - Pharmacia do Brasil Ltda) were similar, in the same way as were the pharmacokinetic parameters Cmax (reference: 11.34 µg/mL; test: 11.11 µg/mL), tmax (reference: 1.67 h; test: 1.71 h), AUC0-t (reference: 201.92 µgxh/mL; test: 198.15 µgxh/mL), AUC0-∞ (reference: 208.25 µg/mL; test: 203.80 µgxh/mL) and t(½)el (reference = 14.05 hours, test = 13.91 hours). The multivariate analysis accomplished through analysis of variance (ANOVA), for assessment of product, group and period effects, revealed the absence of any of these effects in the present study, indicating that the crossover design was properly performed. j The 90% confidence intervals for the ratio of Cmax (93.9 % - 102.6 %), AUC0-t (94.9 % - 101.1 %) and AUC0-∞ (94.6 % - 100.8 %) values for the test and reference products are within the 80 - 125 % interval proposed by FDA and ANVISA. Statistical comparison of AUC0-t , AUC0-∞ and Cmax clearly indicated no significant difference between the two brands of tinidazole 500 mg tablets. Based on the pharmacokinetic and statistical results of this study, we can conclude that the two products are bioequivalent, and can be considered interchangeable in medical practice.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
EuniceEmiko.pdf (3.48 Mbytes)
Fecha de Publicación
2007-09-24
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI