• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.9.2009.tde-16112009-181138
Documento
Autor
Nombre completo
Marina de Freitas Silva
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2009
Director
Tribunal
Serra, Cristina Helena dos Reis (Presidente)
Porta, Valentina
Souza, Jacqueline de
Título en portugués
Determinação da bioequivalência do metronidazol a partir de comprimidos revestidos
Palabras clave en portugués
Biodisponibilidade
Bioequivalência
Espectrometria de massas
Farmacocinética
Metronidazol
Resumen en portugués
O metronidazol é usado no tratamento de infecções causadas por protozoários e naquelas causadas por microrganismos anaeróbicos, no tratamento das formas intestinais e extra-intestinais de amebíase, em tricomoníase e em infecções bacterianas aeróbicas graves. Após administração oral, a absorção é rápida e completa sendo amplamente distribuído, atinge concentração plasmática máxima em 1-2 horas. A meia-vida de eliminação do metronidazol é de 6-12 horas. O objetivo deste trabalho foi avaliar a equivalência terapêutica por meio da bioequivalêmcia entre duas formulações de comprimidos revestidos contendo metronidazol, produzidos por dois fabricantes distintos, permitindo assim a intercambiabilidade entre as formulações. O ensaio de bioequivalência entre o produto teste (FUNED metronidazol) e o produto referência (Flagyl® - Aventis Pharma Ltda.) foi do tipo randomizado, cruzado e aberto. O medicamento foi administrado em dose única de 250 mg de metronidazol aos 24 voluntários sadios. Amostras de sangue foram coletadas até 48 horas após a administração e analisadas por método, desenvolvido e validado, de cromatografia líquida de alta eficiência acoplada à espectrometria de massas (CLAE- MS/MS). As curvas de decaimento plasmático obtidas para o produto teste (FUNED metronidazol) e para o produto referência (Flagyl® - Aventis Pharma Ltda.) foram semelhantes, assim como os parâmetros farmacocinéticos Cmax (teste: 6,66 µg/mL; referência: 6,77 µg/mL), tmax (teste: 1,26 h; referência: 1,90 h), ASC0-t (teste: 73,42 µgxh/mL; referência: 73,56 µgxh/mL), ASC0-∞ (teste: 75,15 µgxh/mL; referência: 75,23 µgxh/mL) e t½el (teste: 8,00 h; referência: 7,76 h). Os intervalos de confiança 90% para a razão de Cmax (92,2 - 106,4 %), ASC0-t (97,2 - 102,5 %) e ASC0-∞ (97,1 - 102,8 %) encontram-se entre 80 e 125 %, intervalo proposto pela ANVISA e FDA para a bioequivalência. A comparação estatística por meio de análise de variância (ANOVA) dos parâmetros Cmax, ASC0-t e ASC0-∞ indica claramente não haver diferença significativa entre os dois produtos contendo 250 mg de metronidazol. Baseado nos resultados farmacocinéticos e estatísticos, conclui-se que os dois produtos são bioequivalentes e, podem ser considerados intercambiáveis na terapêutica.
Título en inglés
Bioequivalence determination of metronidazole from coated tablets
Palabras clave en inglés
Bioavailability
Bioequivalence
Mass sprectrometry
Metronidazole
Pharmacokinetics
Resumen en inglés
Metronidazole is used to treat infections caused by protozoa and those caused by anaerobic microorganisms. It is the drug of choice for the treatment of amebiasis in the intestinal and extra-intestinal forms, trichomoniasis and bacterial aerobic diseases. After oral administration, its absorption is rapid, complete and widely distributed, reaching maximum plasma concentration in 1 to 2 hours. The half-life of elimination of metronidazole is 6 to 12 hours. The objective of this study was to evaluate the therapeutic equivalence through bioavalability between two formulations of tablets containing metronidazole, produced by two different manufacturers, thus allowing the interchangeability between the formulations. The bioequivalence assay between the test product (FUNED Metronidazole) and reference product (Flagyl® - Aventis Pharma Ltda.) was a randomized, crossover and open study. The drug was given at a 250 mg metronidazole single dose to 24 healthy volunteers. Blood samples were collected until 48 hours after administration and analyzed by method, developed and validated in high performance liquid chromatography coupled to mass spectrometry (HPLC - MS / MS). The plasma decay curves obtained for the product test (FUNED metronidazole) and the reference product (Flagyl® - Aventis Pharma Ltda.) were statistically similar in the same way as the pharmacokinetic parameters Cmax (test: 6.66 µg/mL, reference: 6.77 µg/mL), tmax (test: 1.26 h; reference: 1.90 h), AUC0-t (test: 73.42 µgxh/mL, reference: 73.56 µgxh/mL) AUC0-∞ (test: 75.15 µgxh/mL, reference: 75.23). The 90% confidence intervals for the ratio of Cmax (92.2 - 106.4%), AUC0-t (97.2 - 102.5%) and AUC0-∞ (97.1 - 102.8%) are between 80 and 125%, range proposed by ANVISA and FDA for bioequivalence assays. This statistical parameters comparison using analysis of variance (ANOVA) Cmax, AUC0-t and AUC0-∞ clearly indicate no significant difference between the two products containing 250 mg of metronidazole. Based on the pharmacokinetic and statistical results, it is possible to conclude that the two products are bioequivalent and could be considered interchangeable in therapy.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2010-03-23
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.