Master's Dissertation
DOI
https://doi.org/10.11606/D.9.2016.tde-16032016-100730
Document
Author
Full name
Elenice Luduvina da Silva Santos
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2015
Supervisor
Committee
Prado, María Segunda Aurora (President)
Angnes, Lucio
Fonseca, Maria Jose Vieira
Title in Portuguese
Desenvolvimento e validação de metodologia analítica para identificação e doseamento de medicamentos anti-esquistossomose
Keywords in Portuguese
Cromatografia liquida de alta eficiência
Eletroforese capilar
Esquistossomose
Oxamniquina
Validação de métodos analíticos
Abstract in Portuguese
A esquistossomose ou bilharziose, é uma doença produzida por trematódeos do gênero Schistosoma. Dentre as 19 espécies reconhecidas, cinco infectam primariamente o homem: S. mansoni, S. haematobium, S. intercalatum, S. japonicum e S. Mekongi.O número de pessoas com infecção esquistossomótica, em todo o mundo, foi estimado em 200 milhões sendo sua maioria na Ásia e África. Na América do Sul e Caribe encontram-se vários milhões de casos sendo uma estimativa de mais de seis milhões de casos no Brasil. Os fármacos utilizados para o tratamento desta enfermidade são o praziquantel e o oxamniquina, sendo este último o princípio ativo do produto Mansil® cápsulas produzido pela indústria farmacêutica Pfizer. O presente trabalho teve como objetivo desenvolver e validar métodos analíticos por eletroforese capilar (CE) e por cromatografia líquida de alta eficiência (HPLC), rápidos, seletivos e confiáveis para a determinação de oxamniquina em formulações farmacêuticas e de sua impureza (uk-3883), quando houver. A separação cromatográfica foi realizada usando a coluna Thermo® Nucleosil C18 (150 mm x 4,6 mm x 5 µm), com fase móvel constituída por água acidificada com 0,1% ácido ortofosfórico:metanol (40:60 v/v), trabalhando com vazão de 1,0 mL min-1 e volume de injeção de 2 µL. A temperatura da coluna foi controlada em 20 ºC e a detecção foi realizada na região do UV em 254 nm. O tempo de retenção da oxamniquina foi de 1,9 min e da uk-3883 5,1 min. O método por eletroforese capilar de zona (CZE) foi desenvolvido utilizando capilar de sílica fundida de 20 cm (comprimento efetivo) x 50 µm d.i. e eletrólito constituído da solução tampão fosfato de sódio monobásico 30 mmol L-1, pH 2,5 ajustado com ácido orto-fosfórico 10%: metanol 18% v/v. Injeção hidrodinâmica 0,5 psi/3 s; voltagem aplicada de +25 kV, temperatura de 20 ºC e detecção no UV de 254 nm. Os métodos analíticos foram validados de acordo com os requerimentos vigentes da ANVISA, ICH e Farmacopéia Americana. Portanto, os métodos propostos demonstraram linearidade (R2>0,99), precisão (%DPR < 2%), exatidão (>98%, expressado em porcentagem de recuperação) e adequabilidade para a quantificação da oxamniquina em formas farmacêuticas comerciais.
Title in English
Development and validation of analytical methodology for identification and dosing of medicines anti - schistosomiasis.
Keywords in English
Analytical methods validation
Capillary electrophoresis
High performance liquid chromatography
Oxamniquine
Schistosomiasis
Abstract in English
Schistosomiasis or bilharzia, is a disease caused by trematodes of the gender Schistosoma. Among the 19 recognized species, five primarily infect humans: S. mansoni, S. haematobium, S. intercalatum, S. japonicum and S. mekongi. The number of people with schistosomiasis infection worldwide was estimated at 200 million being mostly living in Asia and Africa. In South America and the Caribbean are several million of cases and in Brazil it is stimated of more than six million of cases. The drugs used for the treatment of this disease is praziquantel and oxamniquine, the latter being the active principle of the Mansil® capsules produced by Pfizer pharmaceutical industry. This study aimed to develop and validate fast, selective and reliable analytical methods through capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC), for the determination of oxamniquine in pharmaceutical formulations and its impurity (UK-3883) if any. The chromatographic separation was performed using a Thermo® Nucleosil C18 column (150 mm x 4.6 mm x 5 µm) the mobile phase was composed of water with 0.1% orthophosphoric acid: methanol (40:60 v/v); the flow rate was 1.0 ml min-1. The column temperature was controlled at 20 ° C and the detection was performed with UV detector at 254 nm. The retention time for oxamniquine and its impurity (uk-3883) were 1.9 and 5.1 minutes, respectively. The capillary zone electrophoresis method was developed using an uncoated fused-silica capillary of 20 cm effective length x 50 µm i.d. the electrolyte was composed of 30 mmol L-1 sodium phosphate monobasic buffer solution, pH 2.5 adjusted with ortho-phosphoric acid 10%: 18% methanol v(/v). Samples were injected hydrodynamically at 0.3 psi for 3 s, the detection was made by UV absorption at 254 nm, the capillary temperature was 20ºC and the applied voltage was +25 kV. Analytical methods were validated in accordance with the ANVISA, ICH and United States Pharmacopoeia guidelines. Therefore, the porposed methods showed linearity (R2>0,99), precision (%RSD <2%), accuracy (>98%, expressed as recovery percentage) and suitability for the quantification of oxamniquine in commercial dosage forms.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2016-05-04
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.