Disertación de Maestría
DOI
https://doi.org/10.11606/D.9.2003.tde-15102003-165120
Documento
Autor
Nombre completo
Andréia Montoro Taborianski
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2003
Director
Tribunal
Santoro, Maria Ines Rocha Miritello (Presidente)
Kedor, Erika Rosa Maria
Marchetti, Juliana Maldonado
Título en portugués
Validação de métodos para análise e estudos de estabilidade de anti-retrovirais em preparações farmacêuticas
Palabras clave en portugués
estavudina
estudos de estabilidade acelerada
validação de métodos analíticos
zidovudina
Resumen en portugués
A síndrome da imunodeficiência adquirida é causada pelo vírus da imunodeficiência humana e é caracterizada por provocar depleção física e funcional do sistema imune do organismo, através da infecção citopática de células CD4+. Muitos fármacos anti-retrovirais tem sido desenvolvidos e estão disponíveis comercialmente. Para atuar no controle de qualidade de medicamentos deve-se continuamente estudar o desenvolvimento e a validação de novas metodologias para quantificação de fármacos, para serem aplicadas nos estudos de estabilidade de formulações farmacêuticas e na análise de produtos de degradação. Neste trabalho foram utilizadas duas técnicas analíticas, a espectrofotometria direta no UV/VIS e a cromatografia líquida de alta eficiência (CLAE), para a determinação quantitativa de zidovudina (AZT) e estavudina (d4T).em medicamentos. Ambos os métodos foram validados com relação à linearidade, exatidão, precisão, especificidade e limite de detecção e quantificação. O método validado para a CLAE foi também empregado para a determinação quantitativa da timina, produto de degradação do AZT e da d4T. A metodologia validada por CLAE foi utilizada na realização de estudos de estabilidade acelerada dos anti-retrovirais contidos nas diferentes preparações farmacêuticas. Realizou-se o estudo da estabilidade em três diferentes condições: temperatura ambiente, 40 oC / 75% UR e 50 oC / 90% UR. Tanto a zidovudina (Fabricante A) e estavudina (Fabricante B) apresentaram decaimento cinético de zero ordem com prazos de validade a 50 oC / 90% UR de 10, 3 e 2 meses, respectivamente.
Título en inglés
Validation of analytical methods for analysis and stability studies of anti-retrovirais in pharmaceutical preparations.
Palabras clave en inglés
accelerated stability studies
stavudine
validation of analytical methods
zidovudine
Resumen en inglés
The acquired immunodeficiency syndrome is characterized by causing physical and functional depletion of the organism’s immune system, through the cytophatic infection of CD4+ cells. Several antiretroviral drugs has been developed and commercially made available. In order to assure the quality control of drugs it is necessary to develop and validate new analytical methodologies to perform the quantitative determination of drugs and stability studies of pharmaceutical formulations by determining the drug itself and its degradation products. In this research two analytical techniques, direct UV/VIS spectrophotometry and high performance liquid chromatography (HPLC), were used for the quantitative determination of zidovudine (AZT) and stavudine (d4T) in pharmaceutical preparations. Both methods were validated and parameters like linearity, precision, accuracy, specificity, limit of detection and limit of quantification, were determined. The validated HPLC method was also applied for quantitative determination of timine, a degradation product of AZT and d4T. The validated HPLC method was applied to accelerate stability studies of AZT and d4T in different pharmaceutical preparations. The stability studies were performed at three different conditions: room temperature, 40 oC / 75% RH and 50 oC / 90% RH. Both AZT and d4T (Industry A) and d4T (Industry B) pharmaceutical preparations presented a zero order degradation reaction. The three formulations presented a shelf-life of 10, 3 and 2 months, respectively, at 50 oC / 90% RH.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
taborianski.pdf (1.79 Mbytes)
Fecha de Publicación
2003-11-24
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.