• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.9.2011.tde-15072011-104145
Document
Author
Full name
Michéle Georges Issa
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2011
Supervisor
Committee
Ferraz, Humberto Gomes (President)
Evangelista, Raul César
Rodrigues, Leticia Norma Carpentieri
Title in Portuguese
Avaliação do impacto de diferentes variáveis no ensaio de dissolução intrínseca de metronidazol
Keywords in Portuguese
Biodisponibilidade
Dissolução intrínseca
Metronidazol
Micronização
Sistema de classificação biofarmacêutica
Solubilidade
Abstract in Portuguese
O objetivo do presente trabalho foi avaliar o impacto de diferentes variáveis no ensaio de dissolução intrínseca de metronidazol. Inicialmente, as amostras, com diferentes graus de micronização, foram submetidas à caracterização físico-química, sendo realizados ensaios de solubilidade, tamanho de partícula, análise térmica (DSC/ TG), infravermelho por transformada de Fourier (FTIR), difratometria de raios X (DRX), análise de área superficial pelo método BET, microscopia óptica, densidade verdadeira e densidade compactada. Na sequência, foram realizados os ensaios de dissolução intrínseca segundo um planejamento experimental do tipo fatorial fracionado, sendo cada fator avaliado em três níveis. Para o delineamento, utilizou-se o programa Statistica 8.0. e os fatores estudados foram: velocidade de rotação, pressão utilizada na formação do compactado do fármaco, meio de dissolução e grau de micronização. Os resultados mostraram alteração nas propriedades reológicas do material conforme o aumento do grau de micronização, enquanto as demais propriedades não foram afetadas. Entre os fatores estudados no delineamento, a velocidade de rotação e o meio de dissolução, foram aqueles que exerceram influência significativa na dissolução intrínseca do metronidazol. Embora a solubilidade do fármaco não sofra influência do tamanho de partícula, valores superiores foram observados em HCl 0,1 M, meio em que também foram obtidas as mais elevadas velocidades de dissolução intrínseca (VDIs).
Title in English
Evaluation of the impact of different variables in the intrinsic dissolution test for metronidazole
Keywords in English
Biodisponibility
Biopharmaceutics classification system
Intrinsic dissolution
Metronidazol
Micronization
Solubility
Abstract in English
The purpose of this study is to evaluate the impact of different variables in the intrinsic dissolution test of metronidazol. Initially, the samples, with different levels of micronization, underwent physicochemical characterization, whereby they were tested for solubility, particle size, thermal analysis (DSC/TG), Fourier transform infrared (FTIR) spectroscopy, X-ray diffractometry (DRX), surface area analysis by the BET method, optical microscopy, true density and tapped density. Then, intrinsic dissolution tests were carried out according to fractional factorial experimental planning, with each factor being evaluated on three levels. The Statistica 8.0 software program was used for design, and the factors studied were: rotational velocity, pressure used in the formation of the compressed drug, dissolution medium and level of micronization. The results indicated alterations in the rheological properties of the material, as the level of micronization increased, while the remaining properties were unaffected. Among the factors studied in the design, the rotation speed and the dissolution medium were the factors that exercised the most significant influence on the intrinsic dissolution of metronidazol. Although the solubility of the drug is not influenced by particle size, higher values were observed in HCl 0.1 M, the medium in which the highest intrinsic dissolution rates (IDRs) were also obtained.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2011-08-16
 
WARNING: The material described below relates to works resulting from this thesis or dissertation. The contents of these works are the author's responsibility.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.