Disertación de Maestría
DOI
https://doi.org/10.11606/D.9.2013.tde-15012014-163535
Documento
Autor
Nombre completo
Michele Bacchi Pallastrelli
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2013
Director
Tribunal
Singh, Anil Kumar (Presidente)
Fernandes, Christian
Yonamine, Maurício
Título en portugués
Desenvolvimento e validação de métodos analíticos enantiosseletivos para separação e determinação do esmolol e sotalol
Palabras clave en portugués
Cromatografia líquida de alta eficiência
Eletroforese capilar
Enantiômero
Esmolol
Sotalol
Resumen en portugués
A maioria dos medicamentos normalmente prescritos são comercializados sob a forma racêmica, apesar de se ter conhecimento que a presença de diferentes enantiômeros em uma formulação farmacêutica pode levar a diferentes atividades farmacológicas, farmacocinéticas e perfis toxicológicos. O uso de enantiômeros puros em formulações farmacêuticas pode resultar em melhor ajuste de dose e diminuição dos efeitos adversos, fato que torna estudos a respeito de quiralidade de moléculas fundamental na área farmacêutica. Atualmente, os métodos analíticos mais empregados para a separação e determinação da pureza enantiomérica de compostos são a CLAE-FEQ e eletroforese capilar com seletores quirais. Os enantiômeros de esmolol foram separados através de CLAE-FEQ em fase reversa utilizando coluna Chiralcel-OD-RH (250 x 4,6 mm d.i.), 5 µm. A fase móvel foi composta por perclorato de potássio 100 mM, pH 2,08 : acetonitrila : dietilamina (80:20:0,2) com vazão de 0,5 mL.min-1 e detecção a 220 nm. Os enantiômeros de esmolol também foram separados através de CLAE-FEQ em fase normal utilizando coluna Chiralcel-OD (250 x 4,6 mm d.i.), 10 µm. A fase móvel foi composta por hexano : etanol : dietilamina (75:25:0,2) com vazão de 1,0 mL.min-1 e detecção a 220 nm. Ambos os métodos foram validados, sendo possível considerá-los precisos, seletivos, específicos, exatos e lineares para quantificar os enantiômeros de esmolol em medicamentos. Os testes realizados com cloridrato de sotalol por CLAE não indicaram separação enantiomérica ao serem utilizadas coluna Chiralcel OD®, Chiralcel OD-RH®, Burke e Whelk®. Os ensaios realizados por eletroforese capilar apresentaram separação parcial dos enantiômeros de sotalol e de esmolol, porém houve ausência de reprodutibilidade do método.
Título en inglés
Development and validation of enantioselective analytical methods for separation and determination of esmolol and sotalol
Palabras clave en inglés
Capillary electrophoresis
Enantiomer
Esmolol
High performance liquid chromatography
Sotalol
Resumen en inglés
Most commonly prescribed drugs are marketed as racemic mixtures, even though it is well known that the presence of different enantiomers in a pharmaceutical formulation can lead to different pharmacological, pharmacokinetic and toxicological profiles. The use of pure enantiomers in pharmaceutical formulations can result in better dose adjustment and reduction of side effects, fact which makes studies on molecular chirality important to the pharmaceutical area. Currently, high performance liquid chromatography using chiral stationary phases (CSPs) and capillary electrophoresis with chiral selectors are the most commonly methods employed for the separation and determination of enantiomeric purity of compounds. The enantiomers of esmolol were separated through HPLC using a reversed phase CSP column Chiralcel-OD-RH (250 x 4,6 mm i.d.) 5 µm. The mobile phase was composed of 100 mM potassium perchlorate, pH 2,08 : acetonitrile: diethylamine (80:20:0,2) at a flow rate of 0,5 mL.min-1 and detection at 220 nm. The enantiomers of esmolol were also separated using HPLC-CSP using normal phase column Chiralcel OD (250 x 4,6 mm i.d.), 10 µm. The mobile phase consisted of hexane : ethanol : diethylamine (75:25:0,2) with a flow rate of 1,0 mL.min-1 and detection at 220 nm. Both methods were validated, and it was possible to consider them precise, selective, specific, exact and linear to quantify the enantiomers of esmolol on drugs. HPLC tests conducted with sotalol indicated no enantiomeric separation when Chiralcel OD, Chiralcel OD-RH, Burke and Whelk columns were used. Capillary electrophoresis tests showed partial separation of the enantiomers of sotalol and esmolol, but there was lack of reproducibility.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
MicheleBacchi.pdf (4.49 Mbytes)
Fecha de Publicación
2014-09-02
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.