• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.9.2013.tde-15012014-163535
Document
Author
Full name
Michele Bacchi Pallastrelli
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2013
Supervisor
Committee
Singh, Anil Kumar (President)
Fernandes, Christian
Yonamine, Maurício
Title in Portuguese
Desenvolvimento e validação de métodos analíticos enantiosseletivos para separação e determinação do esmolol e sotalol
Keywords in Portuguese
Cromatografia líquida de alta eficiência
Eletroforese capilar
Enantiômero
Esmolol
Sotalol
Abstract in Portuguese
A maioria dos medicamentos normalmente prescritos são comercializados sob a forma racêmica, apesar de se ter conhecimento que a presença de diferentes enantiômeros em uma formulação farmacêutica pode levar a diferentes atividades farmacológicas, farmacocinéticas e perfis toxicológicos. O uso de enantiômeros puros em formulações farmacêuticas pode resultar em melhor ajuste de dose e diminuição dos efeitos adversos, fato que torna estudos a respeito de quiralidade de moléculas fundamental na área farmacêutica. Atualmente, os métodos analíticos mais empregados para a separação e determinação da pureza enantiomérica de compostos são a CLAE-FEQ e eletroforese capilar com seletores quirais. Os enantiômeros de esmolol foram separados através de CLAE-FEQ em fase reversa utilizando coluna Chiralcel-OD-RH (250 x 4,6 mm d.i.), 5 µm. A fase móvel foi composta por perclorato de potássio 100 mM, pH 2,08 : acetonitrila : dietilamina (80:20:0,2) com vazão de 0,5 mL.min-1 e detecção a 220 nm. Os enantiômeros de esmolol também foram separados através de CLAE-FEQ em fase normal utilizando coluna Chiralcel-OD (250 x 4,6 mm d.i.), 10 µm. A fase móvel foi composta por hexano : etanol : dietilamina (75:25:0,2) com vazão de 1,0 mL.min-1 e detecção a 220 nm. Ambos os métodos foram validados, sendo possível considerá-los precisos, seletivos, específicos, exatos e lineares para quantificar os enantiômeros de esmolol em medicamentos. Os testes realizados com cloridrato de sotalol por CLAE não indicaram separação enantiomérica ao serem utilizadas coluna Chiralcel OD®, Chiralcel OD-RH®, Burke e Whelk®. Os ensaios realizados por eletroforese capilar apresentaram separação parcial dos enantiômeros de sotalol e de esmolol, porém houve ausência de reprodutibilidade do método.
Title in English
Development and validation of enantioselective analytical methods for separation and determination of esmolol and sotalol
Keywords in English
Capillary electrophoresis
Enantiomer
Esmolol
High performance liquid chromatography
Sotalol
Abstract in English
Most commonly prescribed drugs are marketed as racemic mixtures, even though it is well known that the presence of different enantiomers in a pharmaceutical formulation can lead to different pharmacological, pharmacokinetic and toxicological profiles. The use of pure enantiomers in pharmaceutical formulations can result in better dose adjustment and reduction of side effects, fact which makes studies on molecular chirality important to the pharmaceutical area. Currently, high performance liquid chromatography using chiral stationary phases (CSPs) and capillary electrophoresis with chiral selectors are the most commonly methods employed for the separation and determination of enantiomeric purity of compounds. The enantiomers of esmolol were separated through HPLC using a reversed phase CSP column Chiralcel-OD-RH (250 x 4,6 mm i.d.) 5 µm. The mobile phase was composed of 100 mM potassium perchlorate, pH 2,08 : acetonitrile: diethylamine (80:20:0,2) at a flow rate of 0,5 mL.min-1 and detection at 220 nm. The enantiomers of esmolol were also separated using HPLC-CSP using normal phase column Chiralcel OD (250 x 4,6 mm i.d.), 10 µm. The mobile phase consisted of hexane : ethanol : diethylamine (75:25:0,2) with a flow rate of 1,0 mL.min-1 and detection at 220 nm. Both methods were validated, and it was possible to consider them precise, selective, specific, exact and linear to quantify the enantiomers of esmolol on drugs. HPLC tests conducted with sotalol indicated no enantiomeric separation when Chiralcel OD, Chiralcel OD-RH, Burke and Whelk columns were used. Capillary electrophoresis tests showed partial separation of the enantiomers of sotalol and esmolol, but there was lack of reproducibility.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
MicheleBacchi.pdf (4.49 Mbytes)
Publishing Date
2014-09-02
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.