Doctoral Thesis
DOI
https://doi.org/10.11606/T.9.2017.tde-13072017-164922
Document
Author
Full name
Raquel Sofia Cardoso Galante
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2017
Supervisor
Committee
Pinto, Terezinha de Jesus Andreoli (President)
Alvarez-lorenzo, Carmen
Oliveira, Adriano Marim de
Salvador, Pablo Antonio Vasquez
Saramago, Benilde de Jesus Vieira
Title in Portuguese
Esterilização de hidrogéis para aplicações biomédicas
Keywords in Portuguese
Calor húmido
Caracterização
Esterilização
Hidrogel
Irradiação gama
Ozonio
Abstract in Portuguese
A esterilidade é um requisito indispensável para a maioria dos biomateriais. Devido à sensibilidade dos hidrogéis, a sua esterilização apresenta-se como um desafio, sobretudo quando estão em causa nanoestruturas ou a presença de fármacos. O objetivo deste trabalho foi estudar os principais efeitos de diversos métodos de esterilização nas propriedades de diferentes tipos de sistemas à base de hidrogel. Além dos métodos convencionais (calor húmido e radiação gama) foi aferida a aplicabilidade da esterilização por ozono, um processo que embora se revele recente e ainda em fase de desenvolvimento, não deixa, no entanto, de ser bastante promissor. Estudou-se uma formulação de hidrogel natural nanoparticulado à base de quitosano (nanogel), com um largo espectro de possíveis aplicações, e duas formulações de hidrogéis sintéticos para aplicações oftálmicas (modelos de lentes de contato convencional e da nova geração de silicone-hidrogel), com e sem fármacos incorporados. Avaliaram-se alterações nas principais propriedades vitais ao bom desempenho e integridade dos materiais. No caso do nanogel: tamanho médio de partícula, potencial zeta, índice de polidispersão, absorvância, morfologia, estrutura química e citotoxicidade. No caso dos hidrogéis sintéticos: intumescimento, propriedades ópticas, permeabilidade iónica, molhabilidade, morfologia e topografia, estrutura química, propriedades mecânicas, citotoxicidade e perfil de libertação dos fármacos. Para garantir a melhor eficácia dos métodos de esterilização, realizaram-se testes de esterilidade após a contaminação intencional das amostras com diferentes cargas dos respetivos indicadores biológicos. A esterilização por calor húmido revelou-se o método mais agressivo, no caso do nanogel, e o menos agressivo para os hidrogéis sintéticos, quer na presença quer na ausência de fármacos. Relativamente à irradiação gama, para o nanogel, verificou-se que a sua resistência à irradiação aumenta consideravelmente na presença de açucares protetores. Já os hidrogéis sintéticos mostram-se resistentes à técnica, apresentando sinais de degradação evidente apenas para a dose mais elevada (25 kGy). Na presença de fármacos, a irradiação gama mostrou-se inadequada devido à sensibilidade dos mesmos. Os resultados obtidos são promissores no que diz respeito à aplicabilidade da esterilização por ozono, tanto para o nanogel como para os hidrogéis sintéticos, sem fármacos incorporados. Os fármacos sofrem, na generalidade, degradação quando expostos a este agente oxidante. Em suma, face à evidente complexidade dos fatores envolvidos (e.g. natureza, composição e propriedades dos materiais, estabilidade dos fármacos, condições e parâmetros dos processos esterilização), torna-se difícil generalizar os efeitos e prever o resultado dos métodos de esterilização. A escolha do processo mais adequado deve, portanto, ser feita caso a caso.
Title in English
Sterilization of hydrogels for biomedical applications
Keywords in English
Characterization
Gamma irradiation
Hydrogel
Ozone
Steam heat
Sterilization
Abstract in English
Sterility is mandatory requirement for most biomaterials. Because of their known sensitivity, hydrogel sterilization poses as a challenge, particularly when it comes to nanostructures or when drugs are incorporated. The main goal of this work was to study the key effects of different sterilization methods on the properties of different types of hydrogel-based systems. In addition to the conventional methods (steam heat and gamma radiation) the applicability of a promising new ozone method was assessed. Two formulations of synthetic hydrogels for ophthalmic applications (representing conventional contact lenses and new generation silicone-hydrogel contact lens), unloaded and loaded with ophthalmic drugs, were studied; and a natural chitosan-based nanostructured hydrogel (nanogel), with a broad spectrum of possible applications. Changes in the essential properties were evaluated. For synthetic hydrogels: swelling, optical properties, ionic permeability, wettability, morphology and topography, chemical structure, mechanical properties, cytotoxicity and drug release profile. For the nanogel: average particle size, zeta potential, polydispersity index, absorbance, morphology, chemical structure and cytotoxicity. In order to ensure the effectiveness of the sterilization methods, sterility tests were carried out after purposely contaminating the samples with different loads of biological indicators. Seam heat sterilization proved to be the most aggressive method for the nanogel, while being the least aggressive for the synthetic hydrogels in the presence and absence of drugs. Regarding gamma irradiation, the nanogel resistance to irradiation increased considerably in the presence of protective sugars. The synthetic hydrogels were resistant to this technique, showing signs of severe degradation only at the highest dose (25 kGy). In the presence of drugs, gamma irradiation proved to be inadequate due to drug degradation. The obtained results were encouraging with regard to the applicability of ozone sterilization for both the nanogel and the unloaded synthetic hydrogels. The drugs generally undergo degradation when exposed to this oxidizing agent. In view of the evident complexity of the factors involved (e.g. nature, composition and properties of materials, drug stability, conditions and parameters of sterilization processes), it is difficult to generalize the effects and predict the outcome of the sterilization methods. The selection of the most suitable procedure must be made on a case-by-case basis.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2017-07-20
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.