• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.9.2012.tde-08032013-162959
Document
Auteur
Nom complet
Vivian Alves Silverio
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2011
Directeur
Jury
Singh, Anil Kumar (Président)
Mercuri, Lucildes Pita
Santoro, Maria Ines Rocha Miritello
Titre en portugais
Separação, obtenção e utilização de enantômeros puros no controle estereoespecífico de qualidade de medicamentos contendo bisoprolol
Mots-clés en portugais
Bisoprolol
Cromatografia líquida de alta eficiência
Enantiômeros
Separação quiral
Resumé en portugais
A diferença na atividade terapêutica, farmacocinética e / ou farmacodinâmica entre os enantiômeros de fármacos quirais impulsionou a necessidade de estudar e desenvolver métodos para determinação exata e precisa da pureza enantiomérica dos produtos farmacêuticos. Inicialmente, os enantiômeros foram separados em escala analítica. As condições analíticas foram adaptadas para a escala semi-preparativa para a obtenção enantiômeros puros. Os enantiômeros do bisoprolol foram separados através de Cromatografia Líquida de Alta Eficiência. Foi adotado o sistema direto de separação, fase normal, utilizando coluna Chiralcel OD (250 x 4,6 mm id). A fase móvel foi composta por hexano: etanol: dietilamina (80:20:0.2, v / v / v), vazão de 1mL/min e detecção em UV a 273 nm. A separação dos enantiômeros (R)-bisoprolol e (S)-bisoprolol foi obtida com sucesso em escala analítica e semi-preparativa. Considerando as características de uma separação quiral, podemos concluir que os resultados são eficazes, por ser uma separação rápida e seletiva.
Titre en anglais
Separation, preparation and use of pure enantiomers in stereospecific quality control of pharmaceutical products containing bisoprolol
Mots-clés en anglais
Bisoprolol
chiral separation
enantiomers
high-performance liquid chromatography
Resumé en anglais
The difference in therapeutic activity, pharmacokinetics, and / or pharmacodynamics between enantiomers of chiral drugs has raised the need to study and develop methods for accurate and precise determination of enantiomeric purity of pharmaceutical products. Initially, the enantiomers were separation in analytical scale. The analytical conditions were scaled up to semi-preparative level to obtain pure enantiomers. The enantiomers of bisoprolol were separated with high-performance liquid chromatography. Direct separation system was adopted in normal phase mode using Chiralcel OD column (250 x 4.6 mm id). The mobile phase was composed of hexane:ethanol:diethylamine (80:20:0.2, v/v/v), flow rate of 1mL/min and UV detection was made at 273 nm. The separation of enantiomers, (R)-bisoprolol and (S)-bisoprolol was successfully obtained in analytical and semi-preparative scale. Considering the characteristics of a chiral separation, we can conclude that the results are effective, because it is a fast and selective separation.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2013-04-15
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.