Master's Dissertation
DOI
https://doi.org/10.11606/D.9.2012.tde-05092013-102602
Document
Author
Full name
Viviane Benevenuti Silva
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2012
Supervisor
Committee
Santoro, Maria Ines Rocha Miritello (President)
Mercuri, Lucildes Pita
Orsine, Eliane Maria de Almeida
Title in Portuguese
Determinação simultânea de etinilestradiol e drospirenona em contraceptivos orais por cromatografia e fase líquida de alta eficiência e eletroforese capilar
Keywords in Portuguese
Cromatografia líquida de alta eficiência
Drospirenona
Eletroforese capilar
Etinilestradiol
Métodos analíticos
Abstract in Portuguese
O controle da fertilidade é obtido principalmente pela inibição da ovulação por meio da atividade combinada de dois componentes principais: estrogênio e progestina. Desta forma, novas formulações vêm sendo desenvolvidas com baixa dose de etinilestradiol associado a um novo agente progestógeno, a drospirenona, com o objetivo de garantir equilíbrio entre eficácia, segurança e controle de ciclo menstrual. Este trabalho tem como objetivo desenvolver, validar e comparar métodos analíticos para a identificação e quantificação de etinilestardiol e drospirenona presentes em uma mesma formulação por cromatografia em fase líquida de alta eficiência (CLAE) e a eletroforese capilar (EC). O método por CLAE, foi realizado empregando-se uma coluna LiChoCART® 100RP - C18, (125 x 4 mm) 5 µm, fase móvel constituída por MeCN/H2O 50:50 (v/v) e vazão de 1.0 mL min. Utilizou-se um detector UV 200 nm para drospirenona e um de fluorescência λex = 280 nm e λem = 310 nm, para o etinilestradiol. O método por EC foi validado utilizando-se como eletrólito, tampão de tetraborato de sódio 30 mM, dodecil sulfato de sódio 20 mM e acetonitrila 30% a pH 9,2, capilar de sílica fundida de 31,2 cm sendo 21 cm efetivos, com 75 µm de diâmetro interno. O método por CLAE apresentou um coeficiente de correlação (r2) de 0,9989 para o etinilestradiol e 0,999 para a drospirenona. No método por EC, o coeficiente de correlação (r2) encontrado foi de 0,9988 para o etinilestradiol e 0,998 para a drospirenona. Os métodos podem ser considerados eficientes e confiáveis para serem empregados em análise de rotina para controle de qualidade destes produtos farmacêuticos.
Title in English
Simultaneous determination of ethinyl estradiol and drospirenone in oral contraceptive by high performance liquid chromatography and cappilary electrophoresis
Keywords in English
Analytical methods
Capillary electrophoresis
Drospirenone
Ethinylestradiol
High performance liquid chromatography
Abstract in English
The fertility control is achieved mainly by inhibiting ovulation through the combined activity of two main components: estrogen and progestin. Thus, new formulations have been developed associating appropriately low dose of ethinylestradiol to a new drug, the drospirenone, in order to ensure the balance between efficacy, safety and cycle control. The objective of this research was to develop, to validate and to compare two analytical method for separation and quantification of ethinylestardiol and drospirenone using high performance liquid chromatography and capillary electrophoresis (CE). The HPLC method, was performed using a LiChoCART® 100RP - C18, (125 x 4 mm) 5 µm column, a mobile phase constituted of acetonitrile:water (50:50 v/v) and flow rate of 1.0 mL min. UV detection was made for drospirenone at 200 nm coupled with a fluorescence detector at λex= 280 nm and λem = 310 nm for ethinylestradiol. The CE method was validated using a solution of sodium tetraborate buffer 30 mM, sodium dodecil sulphate 20 mM and acetonitrile 30%, pH 9.2 and a fused silica capillary of 31,2 cm with 21 cm effective and 75 µm of diameter. The HPLC method showed a correlation coefficient (r2) of 0.9989 for ethinylestradiol and 0,999 for drospirenone. For CE method, the correlation coefficient was (r2) 0,9988 for ethinylestradiol and 0,9989 for drospirenone. The methods showed to be efficient and reliable, and can be used in routine analysis for quality control of these pharmaceutical preparations.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2013-09-25
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.