Disertación de Maestría
DOI
https://doi.org/10.11606/D.9.2000.tde-19112015-164547
Documento
Autor
Nombre completo
Claudia Regina dos Santos
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2000
Director
Tribunal
Passarelli, Miriam Meyer (Presidente)
Santos, Antonio Cardozo dos
Siqueira, Maria Elisa Pereira Bastos de
Título en portugués
Determinação da 2,5-Hexanodiona urinária por cromatografia em fase gasosa, como indicador biológico da exposição ocupacional ao N-hexano
Palabras clave en portugués
2,5-hexanodiona
Exposição ocupacional
Indicador biológico
N-hexano
Toxicologia
Toxicologia ocupacional
Resumen en portugués
O n-hexano é um solvente usado industrialmente, e pode causar neuropatia periférica. O indicador biológico da exposição ocupacional ao n-hexano é a 2,5-hexanodiona (2,5HD). O objetivo deste estudo foi validar um método para determinação da 2,5HD urinária por cromatografia em fase gasosa, com detetor de ionização de chama. A validação do método levou em consideração dois tipos de tratamento da amostra, com hidrólise ácida e sem hidrólise ácida. Foi utilizada coluna HP1 (15m x 530µm e espessura do filme 1,5µm), gás de arraste He:4,2mL/min. e ciclohexanona como padrão interno. O método apresentou limites de detecção e quantificação, respectivamente 0,05 e 0,1 mg/L, linearidade de 0,1-20mg/mL, r = 0,999, recuperação entre 98-102%, com precisão e exatidão. Para verificar a aplicação do método foram analisadas 87 amostras de trabalhadores de indústrias de calçados (52 do grupo exposto e 35 do grupo controle). As amostras com hidrólise apresentaram níveis de 2,5HD cerca de dez vezes maiores quando comparados com as amostras sem hidrólise, esta diferença foi estatisticamente significante (p<0,0001), mas os níveis de 2,5HD não ultrapassaram o índice Biológico Máximo Permitido (IBMP) de 5mg/g de creatinina, em nenhuma das amostras analisadas. Os resultados indicam que o método validado mostrou aplicação prática para monitorização biológica, e as amostras que passaram pelo tratamento de hidrólise ácida apresentaram maiores níveis de detecção.
Título en inglés
Determination for 2,5-hexanedione urinary by gas chromatography, as a biological indicator of occupational exposure to N-hexane
Palabras clave en inglés
2,5-cyclohexanedione
Biological indicator
N-hexane
Occupational exposure
Occupational toxicology
Toxicology
Resumen en inglés
N-hexane is a solvent used in industries, and can cause peripheral neuropathy. The bioindicator in the biological monitoring of workers exposed to n-hexane is the 2,5-hexanedione (2,5HD). This study was developed in order to validate a method for 2,5HD analysis in urine by gas chromatography with flame ionization detector considering two types of sample preparing with and without acid hydrolysis. The chosen technique was performed with HP1 column measured 15m by 530µm inner bore. Helio was used as the carrier gas at a flow rate of 4,2mL/min. The detection and quantification limits were respectively 0,05 and 0,1 mg/L. A linear relationship (r = 0,999) was observed in the range from 0,1-20mg/mL. The average recovery was 98-102%, with precision and accuracy. To apply this method, 87 samples from shoe factory workers were analyzed (52 exposed group and 35 control group). The samples with acid hydrolysis show levels ten times higher than samples without acid hydrolysis. This difference was statistically significant (p<0,0001), but this levels weren't higher than the Biological Exposure Index (BEI) were recommended value is 5mg/g creatinine, in any of the analyzed samples. These results reveal that the validated method has application for biological monitoring, and the samples with acid hydrolysis showed rates higher than the samples without hydrolysis.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-11-19
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.