• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.9.1999.tde-15012015-165546
Document
Auteur
Nom complet
Isarita Martins
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 1999
Directeur
Jury
Siqueira, Maria Elisa Pereira Bastos de (Président)
Lepera, Jose Salvador
Passarelli, Miriam Meyer
Titre en portugais
Determinação do ácido trans, trans-mucônico urinário por chromatografia líquida de alta eficiência visando a biomonitorização de trabalhadores expostos ao benzeno
Mots-clés en portugais
Ácido trans- trans-mucônico
Análise toxicológica
Benzeno
Biomonitorização
Toxicologia ocupacional
Resumé en portugais
O benzeno é um solvente comprovadamente cancerígeno e, para substâncias com tal característica, não há limites de exposição considerados seguros. Em vista disso, as discussões internacionais e nacionais visam a diminuir, cada vez mais, os níveis de exposição ocupacional permitidos. O ácido trans, trans-mucônico (ttAM) , um produto de biotransformação do benzeno, tem sido preconizado como um bioindicador sensível da exposição ao solvente. Este trabalho foi desenvolvido com o propósito de validar método capaz de detectar o ttAM em urina de indivíduos expostos ao benzeno, bem com estabelecer o melhor período de coleta das amostras. A técnica escolhida foi a cromatografia líquida de alta eficiência (CLAE) com coluna de fase-reversa, Lichrosorb RP 18, e detector de ultra-violeta. O método mostrou-se linear entre 0,2 a 5,0 mg/L (r2 = 0,9943). Os limites de detecção e de quantificação obtidos foram, respectivamente, 0,1 e 0,2 mg/L. A porcentagem de recuperação absoluta média foi de 77,1% e de inexatidão de 27,9%. Os coeficientes de variação médios foram, para a precisão intra-ensaio 7,7 % e, para a interensaio 10,6%. O analito permaneceu estável na matriz por um período de 6 semanas para a concentração de 0,2 mg/L e de 15 semanas, para a 2,0 mg/L, se armazenada em freezer (-20°C) e por até dez dias sob refrigeração (4°C) para os adicionados de 0,2, 2,0 e 5,0 mg/L. Com estes resultados, a validação foi considerada satisfatória. O valor médio obtido nas amostras de trabalhadores ocupacionalmente expostos no final da jornada de trabalho foi de 0,81 mg/g creatinina (mediana=0,62 mg/g creatinina). Estes resultados foram superiores e estatisticamente diferentes (p=0,025) daqueles encontrados em amostras do início da jornada e do dia seguinte, mostrando ser o final da jornada o período que melhor reflete a exposição do dia de trabalho.
Titre en anglais
Determination of trans, trans-muconic acid by liquid chromatografia high efficiency aiming biomonitoring of workers exposed to benzene
Mots-clés en anglais
Acid trans- trans-muconic
benzene
Biomonitoring
Occupational Toxicology
Toxicological Analysis
Resumé en anglais
Benzene is a carcinogenic chemical used in many plants. The national and international discussions aim to low more and more the permitted occupational exposure limit to benzene, although in fact, there is no safe limit to carcinogens. The trans, trans-muconic acid (ttMA), a benzene metabolite, has been recommended as a sensitive bioindicator in the biological monitoring of workers exposed to this solvent. This work was developed in order to validate a method for ttMA analysis in samples of benzene-exposed workers as well as to establish the best sample collecting time. The chosen technique was the high pressure liquid chromatography with reverse-phase column, Lichrosorb RP 18, and UV detection. A linear relationship (r2 =0.9943) was observed in the range from 0.2 to 5.0 mg/L. The detection and quantification limits were respectively 0.1 and 0.2 mg/L. The average recovery was 77.1 % and the inaccuracy (bias) was 27.9 %. Precision, evaluated by variation coefficient, were 7.7 % (intraassay) and 10.6 % (inter-assay). The ttMA remained stable in the matrix during a period of six weeks for the 0.2 mg/L samples and fifteen weeks for the 2.0 mg/L samples, in both cases when stored at - 20°C. In 0.2, 2.0 and 5.0 spiked samples no significant differences were found when conserved at 4°C for ten days. In the occupationally exposed workers, ttMA values were significantly higher in post-shift samples (p = 0.025) than in pre-shift or in those collected in the following day. These results reveal that the end of the shift is the best period to take urine samples for benzene biomonitoring.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-01-15
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.