• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.9.1999.tde-15012015-165546
Documento
Autor
Nombre completo
Isarita Martins
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 1999
Director
Tribunal
Siqueira, Maria Elisa Pereira Bastos de (Presidente)
Lepera, Jose Salvador
Passarelli, Miriam Meyer
Título en portugués
Determinação do ácido trans, trans-mucônico urinário por chromatografia líquida de alta eficiência visando a biomonitorização de trabalhadores expostos ao benzeno
Palabras clave en portugués
Ácido trans- trans-mucônico
Análise toxicológica
Benzeno
Biomonitorização
Toxicologia ocupacional
Resumen en portugués
O benzeno é um solvente comprovadamente cancerígeno e, para substâncias com tal característica, não há limites de exposição considerados seguros. Em vista disso, as discussões internacionais e nacionais visam a diminuir, cada vez mais, os níveis de exposição ocupacional permitidos. O ácido trans, trans-mucônico (ttAM) , um produto de biotransformação do benzeno, tem sido preconizado como um bioindicador sensível da exposição ao solvente. Este trabalho foi desenvolvido com o propósito de validar método capaz de detectar o ttAM em urina de indivíduos expostos ao benzeno, bem com estabelecer o melhor período de coleta das amostras. A técnica escolhida foi a cromatografia líquida de alta eficiência (CLAE) com coluna de fase-reversa, Lichrosorb RP 18, e detector de ultra-violeta. O método mostrou-se linear entre 0,2 a 5,0 mg/L (r2 = 0,9943). Os limites de detecção e de quantificação obtidos foram, respectivamente, 0,1 e 0,2 mg/L. A porcentagem de recuperação absoluta média foi de 77,1% e de inexatidão de 27,9%. Os coeficientes de variação médios foram, para a precisão intra-ensaio 7,7 % e, para a interensaio 10,6%. O analito permaneceu estável na matriz por um período de 6 semanas para a concentração de 0,2 mg/L e de 15 semanas, para a 2,0 mg/L, se armazenada em freezer (-20°C) e por até dez dias sob refrigeração (4°C) para os adicionados de 0,2, 2,0 e 5,0 mg/L. Com estes resultados, a validação foi considerada satisfatória. O valor médio obtido nas amostras de trabalhadores ocupacionalmente expostos no final da jornada de trabalho foi de 0,81 mg/g creatinina (mediana=0,62 mg/g creatinina). Estes resultados foram superiores e estatisticamente diferentes (p=0,025) daqueles encontrados em amostras do início da jornada e do dia seguinte, mostrando ser o final da jornada o período que melhor reflete a exposição do dia de trabalho.
Título en inglés
Determination of trans, trans-muconic acid by liquid chromatografia high efficiency aiming biomonitoring of workers exposed to benzene
Palabras clave en inglés
Acid trans- trans-muconic
benzene
Biomonitoring
Occupational Toxicology
Toxicological Analysis
Resumen en inglés
Benzene is a carcinogenic chemical used in many plants. The national and international discussions aim to low more and more the permitted occupational exposure limit to benzene, although in fact, there is no safe limit to carcinogens. The trans, trans-muconic acid (ttMA), a benzene metabolite, has been recommended as a sensitive bioindicator in the biological monitoring of workers exposed to this solvent. This work was developed in order to validate a method for ttMA analysis in samples of benzene-exposed workers as well as to establish the best sample collecting time. The chosen technique was the high pressure liquid chromatography with reverse-phase column, Lichrosorb RP 18, and UV detection. A linear relationship (r2 =0.9943) was observed in the range from 0.2 to 5.0 mg/L. The detection and quantification limits were respectively 0.1 and 0.2 mg/L. The average recovery was 77.1 % and the inaccuracy (bias) was 27.9 %. Precision, evaluated by variation coefficient, were 7.7 % (intraassay) and 10.6 % (inter-assay). The ttMA remained stable in the matrix during a period of six weeks for the 0.2 mg/L samples and fifteen weeks for the 2.0 mg/L samples, in both cases when stored at - 20°C. In 0.2, 2.0 and 5.0 spiked samples no significant differences were found when conserved at 4°C for ten days. In the occupationally exposed workers, ttMA values were significantly higher in post-shift samples (p = 0.025) than in pre-shift or in those collected in the following day. These results reveal that the end of the shift is the best period to take urine samples for benzene biomonitoring.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-01-15
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.