• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.9.2016.tde-22122015-092807
Document
Auteur
Nom complet
Jessica Silva Salgueiro
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2015
Directeur
Jury
Carvalho, Valdemir Melechco (Président)
Kok, Fernando
Tavares, Marina Franco Maggi
Titre en portugais
Nova estratégia bioanalítica baseada em cromatografia líquida e espectrometria de massas em tandem para a quantificação de aminoácidos em matrizes biológicas: uma ferramenta clínica e experimental
Mots-clés en portugais
Aminoácidos
HILIC
LC-MS/MS
Pareamento iônico
Resumé en portugais
Apesar da rápida expansão das aplicações da cromatografia líquida acoplada à espectrometria de massas em química clínica, a análise de metabólitos de baixo peso molecular e alta polaridade em matrizes biológicas ainda permanece como um grande desafio analítico. Dentre os compostos de grande importância no diagnóstico de doenças metabólicas que ainda carecem de melhores alternativas bioanalíticas destacam-se os aminoácidos. O presente estudo descreve o desenvolvimento e a validação de um novo método para a quantificação de 24 aminoácidos em plasma explorando a cromatografia líquida acoplada a espectrômetros de massas em tandem. Foi construído um método de detecção baseado em SRM (múltiplas reações selecionadas) com duas transições de massas para cada um dos 24 aminoácidos e os 19 padrões internos marcados com isótopos estáveis. Foram avaliadas três estratégias de separação cromatográfica e o melhor desempenho foi obtido com fase reversa com octadecilsilano (C18) com pareamento iônico com o ácido perfluoropentanoico. O método cromatográfico final permitiu a separação dos 24 aminoácidos, com resolução completa dos isômeros: leucina, isoleucina e allo-isoleucina, em 11 minutos incluindo o tempo de re-estabilização da coluna cromatográfica. Os limites de quantificação variaram em 113 fmol a 6 pmol injetados na coluna cromatográfica. A imprecisão obtida nos níveis testados para todos os aminoácidos foi inferior a 14%. O método apresentou linearidade para os intervalos testados chegando a 1,5 mmol.L-1 para vários compostos. Os ensaios de arraste mostraram que os limites máximos obtidos na linearidade não geram nenhuma interferência subsequente. A exatidão do método foi avaliada com amostras provenientes do programa de referência interlaboratorial European Research Network for evaluation and improvement of screening, Diagnosis and treatment of Inherited disorders of Metabolism (ERNDIM) e com o material de referência certificado do National Institute of Standards and Technology (NIST). Todos os analitos mostraram equivalência estatística com o método desenvolvido.
Titre en anglais
New bioanalytical strategy based on liquid chromatography and tandem mass spectrometry for amino acids quantification in biological matrices: a clinical and experimental tool.
Mots-clés en anglais
Amino acids
HILIC
Ion pairing
LC-MS/MS
Resumé en anglais
Despite the widespread use of liquid chromatography coupled to mass spectrometry applications in clinical chemistry, the analysis of low molecular weight and high polar metabolites in biological matrices remains as a major analytical challenge. Notwithstanding the key role played by amino acids in the diagnosis of metabolic diseases, there is still need for improvements in bioanalytical process of these analytes. The present study describes the development and validation of a new method for quantification of 24 amino acids in plasma based on liquid chromatography coupled to tandem mass spectrometry. Detection and quantification were achieved building a selected reaction monitoring method two mass transitions for each 24 amino acids and 19 stable isotope internal standards. Three chromatographic strategies for separation were evaluated, and best performance was achieved using reversed-phase octadecylsilane with perfluropentanoic acid as ion pairing agent. The separation method allowed separation of 24 amino acids with full resolution for isomers leucine, isoleucine and alloisoleucine in 11 minutes, including column equilibration time. The limits of quantification ranged from 113 fmol to 6 pmol (on column injection). Imprecisions for all evaluated levels and amino acids were less than 14%. The method is linear in all clinical intervals and extending up to 1.5 mmol.L-1. Carryover evaluation demonstrated absence of interference in the following injection throughout the analytical interval. Method accuracy was evaluated analyzing reference samples from European Research Network for evaluation and improvement of screening, Diagnosis and treatment of Inherited disorders of Metabolism (ERNDIM) and National Institute of Standards and Technology (NIST). Statistical equivalence was demonstrated for all analytes using the present method.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2016-02-15
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.