Doctoral Thesis
DOI
https://doi.org/10.11606/T.9.2007.tde-15042008-091817
Document
Author
Full name
Alvaro Largura
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2007
Supervisor
Committee
Hirata, Mário Hiroyuki (President)
Gomes, Lígia Ferreira
Osugue, Jo Yoshikuni
Sannazzaro, Carlos Adalberto de Camargo
Sumita, Nairo Massakazu
Title in Portuguese
Desenvolvimento e avaliação de um sistema automatizado biosseguro para o tratamento, reciclagem e descarte de resíduo de microbiologia clínica
Keywords in Portuguese
Ácido acético
Carga microbiana
Hipoclorito de sódio
PCR em tempo real
Resíduos de microbiologia
Abstract in Portuguese
No Brasil, diariamente, são descartadas 2,3 toneladas de meios de cultura potencialmente contaminados com microorganismos. A resolução RDC No 306/2004 da Agência Nacional de Vigilância Sanitária preconiza que os resíduos devem ser tratados antes do descarte, visando à redução da carga microbiana. Foram desenvolvidos 2 métodos para avaliar a sensibilidade e a eficiência, assim como a concentração ideal, de um agente químico (biocida) contra microorganismos contaminantes. O método de difusão com Perfurador Circular de Ágar (PCA) e o método com Perfurador Linear de Ágar (PLA) foram testados com 13 cepas de microorganismos. O biocida avaliado foi a combinação de hipoclorito de sódio (NaClO) com ácido acético (CH3COOH). A partir destes resultados, foi desenvolvido um equipamento automatizado para processar a redução da carga microbiana (SADEMC) dos meios de cultura contaminados. A redução da carga microbiana foi avaliada pelo método quantitativo da reação da transcriptase reversa com detecção em tempo real. O método PCA mostrou ser reprodutível e eficiente para medir a inibição do crescimento bacteriano de um biocida. A concentração mínima de biocida capaz de reduzir o crescimento microbiano foi de 250 ppm para a solução aquosa de NaClO a 0,25% e de 200 ppm para a de CH3COOH a 0,2%. No SADEMC, foi possível processar 4,6kg de meios de culturas em 100 litros da concentração mínima eficaz do biocida por 15 minutos, e atingir uma redução da carga microbiana de, aproximadamente, 1,4E10 unidades formadoras de colônias. Podemos concluir que o SADEMC promove uma redução de carga microbiana compatível com os níveis exigidos pela RDC No. 306; fornece biossegurança na sua manipulação e que resulta em plástico reciclável.
Title in English
Development and evaluation of a biosafe automatized system for treatment, recycling and discarding of clinical microbiology residues
Keywords in English
Acetic acid
Laboratory microbiological waste
Microbial load
Real-time PCR.
Sodium hypochlorite
Abstract in English
In Brazil, daily, 2.3 tons of potentially contaminated cultured medium with microorganisms are discarded. The RDC 306 resolution from the Brazilian National Health Department rules out that residue must be treated prior to discart in order to reduce microbial load. Two methods were developed to evaluate the sensitivity, efficiency and ideal concentration of a chemical agent (biocide) against microorganisms. The Ágar's Diffusion Method by Circular Perforator (PCA) and by Linear Perforator (PLA) were tested with 13 microorganism lines and the biocide composed by Sodium Hypochlorite (NaClO) and its combination with Acetic Acid (CH3COOH). The microbial load reduction was evaluated by the real time reverse transcription-polymerase chain reaction. From the in vitro data, an automatic equipment to process the potentially contaminated culture media (SADEMC) was developed. The PCA method was reproductive and efficient to measure the bacterial growth inhibition induced by the biocide. The minimum biocide concentration capable to reduce the microbial growth was a solution of 0.25% NaClO (250 ppm) and 0.2% CH3COOH (200 ppm). In the SADEMC, the direct exposition of 4.6 kg of culture media in 100 liters of biocide for a period of 15 minutes is capable to reduce the microbial load in approximately 1,4E10 of colony-forming unit. We may conclude that the SADEMC is able to promote a microbial load reduction more intense than the one demanded by the RDC 306 resolution. In addition to that, the SADEMC contemplates personnel safety and allows recycling the plastic residues
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
TeseAlvaroLargura.pdf (1.50 Mbytes)
Publishing Date
2008-04-15
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.