Disertación de Maestría
DOI
https://doi.org/10.11606/D.9.2002.tde-09012015-165654
Documento
Autor
Nombre completo
Alzira Maria da Silva Martins
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2002
Director
Tribunal
Vessoni-Penna, Thereza Christina (Presidente)
Albuquerque, Cristina Northfleet de
Ohara, Mitsuko Taba
Título en portugués
Identificação e verificação da resistência aos sanitizantes dos microrganismos presentes na água destinada ao abastecimento público e em um sistema de purificação
Palabras clave en portugués
Água (Engenharia sanitária e ambiental)
Água contaminada (Cuidados)
Água potável
Água purificada
Análise da água
Bactérias gram-negativas
Determinação da concentração mínima inibitória
Pseudomonas
Tempo de redução decimal
Resumen en portugués
Água purificada para uso em ambientes de saúde e preparação industrial de produtos médico-odonto-hospitalar deve ter uma carga reduzida de contaminação microbiológica e pirogênio. As amostras analisadas foram coletadas em 13 (treze) diferentes estágios de um sistema de purificação de água, sendo isoladas 78 colônias. Para a identificação dos microrganismos foram utilizados: (i) identification system for non-enteric gram-negative rods (api 20 NE, bio Mérieux) e (ii) identification system for enteric and nonfermenter (BBL crystal, Becton Dickinson). De acordo com os resultados pode-se observar uma maior prevalência para Pseudomonas aeruginosa 32,05% (25 colônias dentre as 78 isoladas); Pseudomonas picketti 23,08% (18); Pseudomonas vesiculares 12,82% (10); Pseudomonas diminuta 11,54% (09); Flavobacterium aureum 6,42% (05); Pseudomonas fluorescences 5,13% (04); Acinetobacter Iwoffi 2,56% (02); Pseudomonas putida 2,56% (02); Pseudomonas alcaligenes 1,28% (01); Pseudomonas paucimobilis 1,28% (01), Flavobacterium multivorum 1,28% (01). A eficácia dos agentes sanitizantes utilizados para higienização dos diferentes pontos foi determinada pela concentração inibitória mínima (CIM) e tempo de redução decimal (valor D). Como o hipoclorito de sódio é largamente utilizado na higienização do tanque de água de alimentação, tanque de estocagem da água purificada e nas linhas de distribuição aos pontos de uso, este foi testado frente a todos os microrganismos sendo observado menor resistência para Escherichia coli ATCC 25922 (0.06%=600mg/L), quando comparada a P. aeruginosa isolada e identificada (O,25%=2500mg/L). O tempo de redução decimal (Valor D) da Escherichia coli ATCC 25922 foi de 4 minutos e o valor D da P. aeruginosa isolada e identificada e isolada in house foi de 9 minutos.
Título en inglés
Identification and verification of resistance to the sanitizers of microorganisms present in the water for public supply and a purification system
Palabras clave en inglés
Gram-negative non-fermenting bacteria
Mínimal Inhibitory Concentration (MIC)
Orinking Water
Pseudomonas
Water Purification System
Resumen en inglés
The samples of water, which were taken directly from the public distribution water tank and at twelve different stages of a typical purification system, were analyzed for the identification of isolated bacteria. The efficacy of the chemical sanitizers used in the stages of the system, over the isolated and identified bacteria in the sampling water, was valuated by the minimum inhibitory concentration (MIC and decimal reduction time (D-values). According to the miniature kits used in the identification, there was a prevalence of isolation by P. aeruginosa 32,05 % , P. picketti (Ralstonia picketti) 23,08%, P. vesiculares 12,82%, P. diminuta 11.54%, F.aureum 6,42%, P.fluorescens 5,13%, A.lowffi 2,56%, P.putida 2,56%, P. alcaligenes 1,28%, P.paucimobilis 1,28%, and F. multivorum 1,28%. The efficacy of the agents varied with the concentration and time of contact to reduce a decimal logarithmic (loglO) population (n cycles): (i) 0.5% citric acid (0= 4 min) for 30 min reduced n=7 cycles; (ii) 0.5% chloridric acid (0= 6 min) for 30 min reduced n= 4 cycles; (iii) 70% alcohol (0= 9 min) for 1.0 min (n=0.2 cycles); (iv) 0.5% sodium bisulphite (0= 6 min) for 90 min (n=14 cycles); (v) 0.4% sodium hydroxide (0= 8 min) for 30 min (n=3.0 cycles); (vi) 0.5% sodium hypochlorite (0=9 min) for 180 min (n = 19 cycles); (vii) mixture of hydrogen peroxide (2,2%) plus peracetic acid (0.45%), 0= 6 min, contact time of 180 min, reduced n = 32 cycles of the population. The sterility assurance level (SAL) of 10-6 was attained for the 0.5% sodium hypochlorite solution applied in the water purified storage tank and distribution loop; and for the mixture of H2O2 plus peracetic acid, used in the reverse osmose and in the deionizator systems.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-01-09
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.