Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.88.2009.tde-30112009-160515
Document
Auteur
Nom complet
Rodrigo Lins Pagliai
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2009
Directeur
Jury
Goncalves, Debora (Président)
Faria, Ronaldo Censi
Nitschke, Marcia
Titre en portugais
Comparação do uso da tirosinase purificada e na forma de extrato bruto enzimático em biossensores amperométricos para a detecção de catecol
Mots-clés en portugais
Biossensores
Eletroquímica
Litografia
Monocamadas automontadas
Resumé en portugais
Este trabalho tem como principal objetivo comparar as respostas de biossensores amperomé-tricos preparados a partir do uso de uma enzima, a tirosinase (polifenoloxidase, PFO), quando nas formas purificada e adquirida comercialmente e de extrato bruto enzimático do fruto do abacate (Persea Americana). As soluções de PFO apresentaram valores de atividades enzimá-ticas de 479 unidades de enzimas ativas por mililitro (UA mL-1) (purificada) e 259 UA mL-1 (extrato bruto). A enzima nas duas formas (pura e como extrato bruto) foi imobilizada quimi-camente em substratos de Au modificados com monocamadas automontadas (self-assembly monolayers, SAMs) de ácido mercaptopropiônico (MPA) pela técnica de impressão por mi-crocontato (CP). Os biossensores foram preparados sobre substratos de Au modificados por CP com um molde elastomérico de polidimetilsiloxano (PDMS), cujas trilhas paralelas de 100 m foram produzidas pela cura polimérica sobre um molde mestre de GaAs. A réplica de PDMS se mostrou fiel em relação ao molde mestre nos picos e vales, mas apresentou defeitos na borda dos moldes. Com o objetivo de otimizar o funcionamento dos biossensores, eles fo-ram caracterizados pelas técnicas de voltametria cíclica e cronoamperometria com um sistema de análise de injeção em fluxo (FIA) em meio de catecol a diferentes concentrações. Os po-tenciais de oxidação do catecol nos eletrodos de Au modificados foram observados em 418 e 365 mV, em pHs ótimos de funcionamento de 7,0 e 7,2, e com limites de detecção de 6,65 nmol L-1 e 4,65 nmol L-1 para os biossensores com a enzima purificada e com o extrato bruto, respectivamente. A saturação dos sensores teve início a uma concentração de catecol de 0,02 mol L-1. Com estes resultados, mostramos que é possível o preparo de biosensores com um baixo custo, eficientes e miniaturizadas a partir do uso da PFO na forma extrato bruto do fruto do abacate para a detecção de compostos fenólicos, tal como catecol, abrindo assim a possibi-lidade de uso destes biossensores na análise e no monitoramento de pesticidas presentes no solo e na água.
Titre en anglais
Comparison of tyrosinase biosensors from the purified enzyme and in the crude extract form for catechol detection.
Mots-clés en anglais
Biosensors
Electrochemistry
Lithography
Self-assembly monolayers
Resumé en anglais
The main objective of this master thesis is to compare the performance of amperometric biosensors prepared using the purified tirosinase (PPO) enzyme, (commercially acquired) and the PPO present in the enzymatic crude extract from the avocado fruit (Persea Americana). The PPO solutions had 479 units of active enzyme per milliliter (UA mL-1) (purified) and 259 UA mL-1 (crude extract). Both forms of the enzyme (purified and crude extract) were chemically immobilized on gold substrates patterned with 3-mercaptopropionic acid (MPA) self assembled monolayers (SAMs), using the microcontact printing (CP) technique. The biosensors were prepared on gold subtracts patterned using CP with a polydimethylsiloxane (PDMS) elastomeric mold, that was shaped in the form as tracks using a gallium arsenate master mold. The PDMS mold was quite similar to the master mold in its peaks and valleys, but defects were found on the edges. In order to optimize the parameters of the biosensors , they were characterized using cyclic voltammetry and chronoamperometry techniques in a FIA system by cathecol injections at different concentrations. The oxidation potentials for the cathecol analysis using the patterned biosensors were observed at 418 and 365 mV, the optimum pH were 7,0 and 7,0, with detection limits of 6,65 nmol L-1 and 4,65 nmol L-1 for the purified enzyme and crude extract biosensors, respectively. The biosensors saturation point started at 0,02 mol L-1 of cathecol concentration. With this results, we demonstrate that it is possible to use miniaturized, efficient, low cost biosensors based on tyrosine from the avocado´s fruit crude extract to detect phenolic compounds, as the cathecol. This expands the possibility of using this biosensors in the analysis and monitoring pesticides in water and soil.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
pagliaifinal.pdf (1.42 Mbytes)
Date de Publication
2010-02-23
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.