• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.88.2007.tde-01122014-112608
Document
Auteur
Nom complet
Elys Raquel Andrade Ferreira
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2007
Directeur
Jury
Goncalves, Debora (Président)
Guimaraes, Francisco Eduardo Gontijo
Mascaro, Lucia Helena
Titre en portugais
Filmes de polipirrol como matrizes para a imobilização da polifenol oxidase e aplicação como biossensores amperométricos na análise de compostos fenólicos
Mots-clés en portugais
Biosensores
Polifenol oxidase (PFO)
Polipirrol (PPI)
Resumé en portugais
Nesta dissertação, a polifenol oxidase (PFO) como extrato bruto de abacate (Persea americana) foi imobilizada em filmes de polipirrol (PPI) sintetizados eletroquimicamente utilizando o glutaraldeído (GA) como um agente de ligação entrecruzada. Os filmes PPI e PPI/PFO-GA foram caracterizados por eletroquímica, principalmente voltametria cíclica, sendo avaliadas a eletroatividade e a reversibilidade eletroquímica. A detecção de compostos fenólicos em soluções padrão foi feita por cronoamperometria, tendo um controle sobre a concentração dos compostos. O processo de transferência de massa foi monitorado com uma microbalança de cristal de quartzo eletroquímica. Os resultados indicaram uma boa reprodutibilidade das medidas na detecção dos compostos fenólicos. A estabilidade do biossensor em uma solução tampão manteve-se durante 27 dias, um resultado aceitável já que é encontrado na literatura um tempo de vida estável para sistemas semelhantes em tomo de 30 dias
Titre en anglais
Polypyrrole film as matrix for the immobilization of polyphenol oxidase and application as amperometric biosensors in the analysis of phenolic
Mots-clés en anglais
Biosensors
Polyphenol oxidase (PPO)
Polypyrrole (PPY)
Resumé en anglais
In this dissertation, polyphenol oxidase (PPO) as crude extract of avocado (Persea americana) was immobilized on electrochemical1y synthesized polypyrrole (PPY) films using glutaraldehyde (GA) as a crosslinking agent. PPY and PPY/PPO-GA films were electrochemical1y characterized, mainly by cyclic voltametry, where electroactivity and electrochemical reversibility were evaluated. The detection of phenolic compounds in standard samples was made by chronoamperometry with a control over the compound concentration. The process of mass transfer was monitored with an electrochemical quartz crystal microbalance (EQCM). Our results indicated a good repeatability of the measurements for the detection of phenolic compounds. The stability of biosensor in a buffer solution has remained for 27 days, a result acceptable since it is found in the literature a time of life stable for similar systems around 30 days
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2014-12-03
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.