Tesis Doctoral
DOI
https://doi.org/10.11606/T.88.2010.tde-01032010-144421
Documento
Autor
Nombre completo
Dante Luis Chinaglia
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 1999
Director
Tribunal
Faria, Roberto Mendonça (Presidente)
Altafim, Ruy Alberto Corrêa
Hessel, Roberto
Oliveira, Luiz Nunes de
Sandonato, Gilberto Marrega
Título en portugués
Mecanismos de transporte de cargas injetadas por canhão de elétrons de baixa energia em meios dielétricos.
Palabras clave en portugués
Acelerador de elétrons
Corrente induzida por radiação
Curva de emissão
Teflon FEP
Resumen en portugués
Neste trabalho realizamos uma série de medidas de correntes elétricas através de amostras de polímeros isolantes submetidos a radiação por feixe eletrônico, amostras essas inserida em um circuito em modo de corrente. A energia do feixe incidente foi sempre tal que não atravessava totalmente a amostra, depositando em seu interior excesso de carga negativa. A polaridade dessa carga foi determinada pela curva de emissão secundária. Como a energia do feixe foi sempre muito superior à energia EII (abaixo dessa energia o número de elétrons injetados pelo feixe é menor que os arrancados para fora da amostra, e acima desse valor o contrário ocorre), as amostras usadas (polifluoretileno-propileno, polietileno de alta densidade e polietileno de baixa densidade) foram carregadas negativamente. Devido à radiação parcialmente penetrante, cada amostra foi dividida em duas regiões distintas: irradiada e não-irradiada. Na região não-irradiada permanece a condutividade intrínseca do material, enquanto na irradiada a condutividade foi muito aumentada devido à geração de portadores secundários pela radiação. As curvas de corrente foram medidas durante e após a irradiação sob diferentes campos elétricos aplicados externamente. Vários modelos teóricos foram aplicados para explicar os resultados de correntes medidas. O mais simples foi o Modelo Caixa, onde a penetração dos primários era um valor fixo r, dividindo a amostra em condutividade induzida g1 de 0 a r, e condutividade intrínseca gi, de r a L, sendo g1 gi (L é a espessura da amostra). O modelo mais sofisticado levou em conta uma região Δr em torno de r pois considera que o freamento dos elétrons não ocorre todos no mesmo ponto, mas tem uma dispersão em tomo de um ponto r. Por esse motivo a condutividade induzida é dependente da posição, e num caso mais geral depende também do tempo. Durante a irradiação da amostra inserida no circuito de medida, pode ocorrer injeção pelos eletrodos alterando, em determinadas circunstâncias, a polaridade do excesso de carga. Como resultado dos ajustes teórico-experimentais vários parâmetros elétricos dos materiais foram obtidos.
Título en inglés
Low energy electron beam injected charge and its transport mechanisms in dieletrics.
Palabras clave en inglés
Electron beam
Emission curve
Radiation induced conductivity
Teflon FEP
Resumen en inglés
This work presents several electric current measurements in dieletric polymers under irradiation by electron beam. The samples were irradiated in a current mode circuit. The energy of the beam provided a negative charge profile charge in the bulk o the sample. The polarity of the deposited charge was determined by a secundary emission curve. Since the energy of the beam was always bigger tham EII (which defines the balance between the injected electrons and the emitted ones; below EII the sample became positively charged, while above it is negatively charged) the samples (polyethylene propylene, high density polyethylene and low density polyethylene) were always negatively charged. Each irradiated sample was divided in two regions: the irradiated region and the non-irradiated one. Due to the secondary generated carries, the condutivity of the irradiated region gi was orders of magnitude higher than the intrinsic condutivity g1. The eletric currents were measured during and after the irradiation, under different external electric fields. Several theoretical models were used to explain the experimental results. The simplest one, the box models, considers the induced condutivity gb from 0 to r, and the intrinsic condutivity gi from r to L (L being the sample thickeness). The more sophisticated model, on the other hand, considers a range value Δr around the point r. It means that the stopping power is not abruptly but rather is distributed in a region Δr around the point r. For this reason the induced conductivity depends on the position, and in a more general framework, also in time. During the irradiation, carriers are injected to the sample by the electrodes, and in certain conditions the excess of charge has its polarity inverted. From the theoretical-experimental fittings important electrical parametes of the materials were obtained.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2010-03-04
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.