Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.87.2017.tde-21022017-113927
Document
Auteur
Nom complet
Gabriel Pinna Feliciano
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2016
Directeur
Jury
Azevedo, Anita Mitico Tanaka (Président)
Crespo, Joaquín Cabrera
Gonçalves, Viviane Maimoni
Titre en portugais
Inovação no processo de fracionamento de plasma humano através do uso de cromatografia líquida de pseudoafinidade.
Mots-clés en portugais
Cromatografia líquida
FIX
FVIII
Proteínas dependentes de vitamina K
Pseudoafinidade
Troca aniônica
Resumé en portugais
Neste trabalho mostramos que o método de purificação empregando a coluna ANX Sepharose FF, alternando eluições com CaCl2 (pseudoafinidade) e NaCl, permite obter concentrados do complexo protrombínico e do fator VIII em uma etapa cromatográfica. Testamos as colunas ANX e Q Sepharose FF, monolito QA e membrana Sartobind Q e os tampões citrato, MES e Bis-Tris. Empregando a ANX Sepharose FF e o tampão citrato as proteínas do complexo protrombínico eluiram com CaCl2 25 mM e o FVIII com NaCl 500mM. A recuperação da atividade de FVIII foi de cerca de 60% e o fator de purificação de 220 vezes. Na fração contendo as proteínas do complexo protrombínico foram identificadas por espectrometria de massas a presença de fibrinogênio, proteína C4 do complemento e C4b Binding Protein. A análise das frações mostra que a presença destas proteínas não é devido à variação da concentração de CaCl2, possivelmente se deve à difusão lenta destas através da resina. Mais de 99% das proteínas do plasma não são adsorvidas na coluna e podem ser purificadas em etapas posteriores.
Titre en anglais
Innovation in human plasma fractionation process using liquid pseudo-affinity chromatography.
Mots-clés en anglais
Anion-exchange
FIX
FVIII
Liquid chromatography
Pseudo-affinity
Vitamin K dependent proteins
Resumé en anglais
In this study we showed that the purification method employing the anion exchange column ANX Sepharose FF, and alternating CaCl2 (pseudoaffinity) and NaCl elutions, allows us to obtain concentrates of prothrombin complex proteins and factor VIII in a single chromatographic step. We tested the ANX, Q Sepharose FF and QA monolithic column and Sartobind Q membrane and the citrate, MES and Bis-Tris buffers. Using ANX Sepharose FF and the citrate buffer the prothrombin complex proteins eluted with 25 mM CaCl2 and FVIII with 500 mM NaCl. FVIII activity recovery was approximately 60% with a purification factor of 220. In the fraction containing the prothrombin complex proteins presence of fibrinogen, complement C4 and C4bBinding Protein were identified by mass spectrometry. Analysis of the fractions showed that their presence is not due to the variation of concentration of CaCl2, but possibly due to their slow diffusion through the resin. More than 99% of the plasma proteins are not adsorbed in the column and can be purified in following chromatographic steps.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-02-21
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.