Master's Dissertation
DOI
https://doi.org/10.11606/D.87.2016.tde-19102016-142754
Document
Author
Full name
Thiago Nepomuceno Silva
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2016
Supervisor
Committee
Schneider, Rene Peter (President)
Araujo, Welington Luiz de
Mehnert, Dolores Ursula
Title in Portuguese
Avaliação dos efeitos da adição de L-cistina e sais biliares na técnica de H2S na detecção de contaminação fecal em ambientes aquáticos.
Keywords in Portuguese
Colilert
Contaminação fecal
Membrana filtrante
Sulfeto de hidrogênio
Teste H2S
Abstract in Portuguese
As fontes hídricas disponíveis para o consumo humano vêm sendo comprometidas. Para resolver este problema, várias técnicas de detecção de contaminação fecal foram desenvolvidas. Em 1982, Manja e colegas desenvolveram método H2S que é simples, rápida e de baixo custo e detecta bactérias produtoras de H2S e, assim, a contaminação fecal. Neste trabalho foi analisada a eficácia de detecção de micro-organismos produtores de H2S frente a adição de L-cistina (125mg/L e 250mg/L) e desoxicolato de sódio (DS) (0,1% e 0,3%) e na presença de bactérias não produtoras de H2S para verificar se a presença destas bactérias interferem na detecção dos isolados H2S+. Assim, comparou-se o teste H2S com a membrana filtrante e o Colilert®. Os resultados deste estudo indicam que o meio H2S com adição de 0,3% de desoxicolato de sódio se mostrou mais rápido e sensível. Quando comparado com outras metodologias clássicas, o meio com 0,3% apresentou uma ligeira queda na sensibilidade mas o método H2S se mostrou mais sensível que o Colilert.
Title in English
Effect evaluation of L-cystine and bile salts in H2S method for fecal contamination detection in water environment.
Keywords in English
Colilert®
Fecal contamination
H2S strip test
Hydrogen sulphide
Membrane filtration
Abstract in English
Water supply for human consumption have been compromised. Several detection methods for fecal contamination have been developed to solve this problem. Manja and co-workers (1982) developed a simple, fast and low-cost method for fecal contamination based on detection of sulfate-reducing bacteria, the H2S method. This work aimed to analyse the detection efficiency of the H2S method under different conditions: with L-cystine (125mg/L e 250mg/L) and sodium deoxycholate (0.1% e 0.3%). Also, non-sulfate-reducing bacteria interference were evaluated. Comparison tests were made through membrane filtration and Colilert®. Our results indicate a faster and more sensible for the 0.3% sodium deoxycholate condition. Compared to other classic methodologies, the 0.3% sodium deoxycholate condition slightly decrease the sensibility. However the H2S method was more sensitive than the Colilert one.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2016-10-19
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.