• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.87.2016.tde-19102016-142754
Documento
Autor
Nombre completo
Thiago Nepomuceno Silva
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2016
Director
Tribunal
Schneider, Rene Peter (Presidente)
Araujo, Welington Luiz de
Mehnert, Dolores Ursula
Título en portugués
Avaliação dos efeitos da adição de L-cistina e sais biliares na técnica de H2S na detecção de contaminação fecal em ambientes aquáticos.
Palabras clave en portugués
Colilert
Contaminação fecal
Membrana filtrante
Sulfeto de hidrogênio
Teste H2S
Resumen en portugués
As fontes hídricas disponíveis para o consumo humano vêm sendo comprometidas. Para resolver este problema, várias técnicas de detecção de contaminação fecal foram desenvolvidas. Em 1982, Manja e colegas desenvolveram método H2S que é simples, rápida e de baixo custo e detecta bactérias produtoras de H2S e, assim, a contaminação fecal. Neste trabalho foi analisada a eficácia de detecção de micro-organismos produtores de H2S frente a adição de L-cistina (125mg/L e 250mg/L) e desoxicolato de sódio (DS) (0,1% e 0,3%) e na presença de bactérias não produtoras de H2S para verificar se a presença destas bactérias interferem na detecção dos isolados H2S+. Assim, comparou-se o teste H2S com a membrana filtrante e o Colilert®. Os resultados deste estudo indicam que o meio H2S com adição de 0,3% de desoxicolato de sódio se mostrou mais rápido e sensível. Quando comparado com outras metodologias clássicas, o meio com 0,3% apresentou uma ligeira queda na sensibilidade mas o método H2S se mostrou mais sensível que o Colilert.
Título en inglés
Effect evaluation of L-cystine and bile salts in H2S method for fecal contamination detection in water environment.
Palabras clave en inglés
Colilert®
Fecal contamination
H2S strip test
Hydrogen sulphide
Membrane filtration
Resumen en inglés
Water supply for human consumption have been compromised. Several detection methods for fecal contamination have been developed to solve this problem. Manja and co-workers (1982) developed a simple, fast and low-cost method for fecal contamination based on detection of sulfate-reducing bacteria, the H2S method. This work aimed to analyse the detection efficiency of the H2S method under different conditions: with L-cystine (125mg/L e 250mg/L) and sodium deoxycholate (0.1% e 0.3%). Also, non-sulfate-reducing bacteria interference were evaluated. Comparison tests were made through membrane filtration and Colilert®. Our results indicate a faster and more sensible for the 0.3% sodium deoxycholate condition. Compared to other classic methodologies, the 0.3% sodium deoxycholate condition slightly decrease the sensibility. However the H2S method was more sensitive than the Colilert one.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-10-19
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.