• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.87.2010.tde-01032011-181049
Document
Auteur
Nom complet
Ana Claudia Pacheco
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2010
Directeur
Jury
Maria, Durvanei Augusto (Président)
Iwamura, Edna Sadayo Miazato
Ruiz, Itamar Romano Garcia
Titre en portugais
Emprego de miniSTRs "non-CODIS" em amostras biológicas de DNA forense.
Mots-clés en portugais
DNA
Eletroforense capilar de zona
Genética (técnicas)
Identificação (humano)
Investigação criminal
Reação em cadeia por polimerase
Resumé en portugais
Foram analisadas 80 amostras de casos forenses criminais do Laboratório de DNA do Instituto de Criminalística de São Paulo. O DNA foi extraído de materiais cadavéricos, vestígios de crimes sexuais e de locais de crimes. A quantificação se deu por PCR em tempo real e a amplificação por PCR, em 2 reações triplex, dos miniSTRs non-CODIS D10S1248, D14S1434 e D22S1045 (NCO01) e D1S1677, D2S441 e D4S2364 (NCO02), com posterior eletroforese capilar para detecção dos produtos fluorescentes. Avaliou-se o grau de conservação das amostras e a qualidade dos perfis genéticos obtidos. Houve concordância nas dificuldades entre diferentes amostras quando comparado com as abordagens tradicionais. Confirmou-se a sensibilidade e robustez dos sistemas utilizados, bem como a vantagem em se aumentar o número de regiões analisadas, principalmente em casos complexos, mas foram constatadas desvantagens de procedimentos tipo in-house. É necessário o estudo das frequências alélicas destes loci para a população brasileira, que possam ser incorporadas nos cálculos estatísticos dos laudos.
Titre en anglais
The use of "non-CODIS" miniSTRS in forensic DNA biological samples.
Mots-clés en anglais
Capillary zone eletroforense
Criminal investigation
DNA
Genetics (technical)
Identification (human)
Polymerase chain reaction
Resumé en anglais
80 forensic casework samples from the DNA Laboratory of the Criminalistics Institute of São Paulo were analyzed. DNA was extracted from corpse, sexual assault and crime scene evidence. The extractions were quantified using real-time PCR, amplified by two triplex PCR reactions of the non-CODIS miniSTRs D10S1248, D14S1434, D22S1045 (NC01) and D1S1677, D2S441, D4S2364 (NC02), followed by capillary electrophoresis to detect the fluorescent products. The sample preservation and quality of the genetic profiles obtained were evaluated. The results were compared to the previous obtained with the routine techniques employed in the laboratory and there was concordance in the relative difficulties. The sensibility and robustness of the systems employed were confirmed, as well as the advantages in increasing the number of loci studied, mainly in complex cases, although the in-house procedures were considered a disadvantage. The establishment of brazilian population allele frequencies for these loci is necessary for the statistical calculations of the forensic reports.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2011-08-17
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.