Doctoral Thesis
DOI
https://doi.org/10.11606/T.86.2006.tde-29112006-153307
Document
Author
Full name
Wilson Negrão Macedo
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2006
Supervisor
Committee
Zilles, Roberto (President)
Andrade, Adnei Melges de
Diniz, Antonia Sonia Alves Cardoso
Pinho, João Tavares
Rüther, Ricardo
Title in Portuguese
"Análise do fator de dimensionamento do inversor (FDI) aplicado a sistemas fotovoltaicos conectados à rede (SFCR)"
Keywords in Portuguese
conexão a rede
geração distribuída
Sistemas fotovoltaicos
Abstract in Portuguese
Esta tese apresenta a análise de resultados teóricos, correspondentes a simulações numéricas para várias localidades brasileiras, e experimentais, relativos ao sistema fotovoltaico conectado à rede elétrica (SFCR), de 11,07 kWp, instalado na fachada do prédio da administração do Instituto de Eletrotécnica e Energia da Universidade de São Paulo (IEE/USP), enfatizando-se a influência da capacidade relativa entre o inversor e o gerador fotovoltaico, também conhecido como Fator de Dimensionamento do Inversor (FDI). Apesar das diferentes localidades estudadas e dos diferentes tamanhos dos geradores fotovoltaicos, constatou-se que, para uma determinada faixa de FDI, as produtividades anuais obtidas em kWh/kWp não diferem significativamente, indicando que o cuidado com a escolha de bons equipamentos torna-se mais relevante em termos energéticos do que a própria relação FDI.
Title in English
Análise do Fator de Dimensionamento do Inversor (FDI) aplicado a Sistemas Fotovoltaicos Conectados à Rede (SFCR).
Keywords in English
conexão à rede
energia solar.
geração distribuída
sistemas fotovoltaicos
Abstract in English
This thesis presents the analysis of theoretical results, corresponding to numeric simulations for several locations in Brazil, and experimental results, relative to the grid-connected photovoltaic system (GCPVS) of 11.07 kWp, installed in the facade of the administration building of the Instituto de Eletrotécnica e Energia da Universidade de São Paulo (IEE/USP), emphasizing the influence of the relative size between the inverter and the photovoltaic generator, also known as Sizing Factor of the Inverter (SFI). In spite of the different location studied and of the different sizes of the photovoltaic generators, it was verified that for a SFI's certain range, the annual yields obtained in kWh/kWp do not differ significantly, indicating that the care with the choice of good equipament, becomes more important in terms of energey production than the relation SFI itself.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
TeseWilson1.pdf (19.53 Mbytes)
Publishing Date
2007-05-03
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.