  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.86.1994.tde-20122011-172519
Document
Auteur
Nom complet
Ari Ferreira de Abreu
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 1994
Directeur
Jury
Sauer, Ildo Luís (Président)
Fagá, Murilo Tadeu Werneck
Jabardo, Jose Maria Saiz
Titre en portugais
Análise da eficiência energética e da viabilidade dos ciclos de absorção na frigorificação de cargas
Mots-clés en portugais
eficiência energética
Resumé en portugais
Este trabalho aborda a problemática do transporte de carga frigorificada, sob a ótica da eficiência energética da unidade frigorífica. São propostas alternativas para conservação de alimentos, independentemente do frio. Embora incapazes de substituir totalmente o frio, podem ser uma alternativa em vários casos. É analisada a tecnologia de frigorificação atualmente empregada, enfocando custos do sistema, eficiência energética e efeitos da atual tecnologia sobre o meio ambiente. É desenvolvido o projeto preliminar de uma unidade de refrigeração por absorção, que é analisado comparativamente com as unidades por compressão a vapor. Este estudo mostra que o sistema de refrigeração por absorção pode ser viável em muitas aplicações onde não se dispõe de energia térmica ou mecânica.
Titre en anglais
Analysis of energy efficiency and viability of the absorption refrigeration cycle load
Mots-clés en anglais
energy efficiency
Resumé en anglais
This study analyses refrigerated freigth transportation, under the scope of refrigeration energy effeciency. There are several alternatives for food conservation, independently of refrigeration. These existing technologies are not capable of completely replacing refrigeration, but they could be utilized in many cases. The refrigeration techonology currently used is analysed, focusing on system costs, energy efficiency and environmental impacts. A preliminary design of an absoption system was done and an analysis was performed comparating it with the compression units. Conclusive analysis of the system will depend of the evaluation of the experimental unit. This study shows that refrigeration by absortion could be viable in various aplications where no electricity or mechanical energy are available.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.