• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.86.2005.tde-20122005-115553
Document
Auteur
Nom complet
Miltom Shigihara
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2005
Directeur
Jury
Piantini, Alexandre (Président)
Janiszewski, Jorge Mieczyslaw
Pinto Junior, Osmar
Titre en portugais
"Avaliação de correntes de descargas atmosféricas através de medições diretas em estruturas altas"
Mots-clés en portugais
corrente "contaminada"
descargas atmosféricas
estruturas elevadas
modelos de descargas de retorno
Resumé en portugais
As características das correntes das descargas atmosféricas têm fundamental importância na coordenação de isolamento e nos projetos de equipamentos de sistemas de transmissão e de distribuição de energia. As curvas de distribuição de freqüência cumulativa da CIGRE relativas aos principais parâmetros da primeira e das descargas subseqüentes, freqüentemente utilizadas para avaliar o desempenho das linhas de transmissão e distribuição, se referem a dados obtidos através da medição de correntes de descargas negativas em estruturas elevadas. Entretanto, as correntes medidas nesses objetos podem apresentar distorções associadas às diferenças de impedâncias entre o canal, o objeto e o aterramento. Em outras palavras, a corrente em tais objetos pode variar substancialmente em função do ponto escolhido para medição, bem como apresentar diferenças significativas em relação à corrente no canal da descarga. Essas correntes são denominadas “contaminadas". As curvas da CIGRE relativas às amplitudes, tempos de frente e taxas de crescimento das correntes se referem às correntes “contaminadas", uma vez que as reflexões que ocorrem no topo e na base de objetos elevados não foram levadas em consideração no processo de construção dessas curvas. Assim, o tratamento desses dados necessita ser revisto. Por outro lado, o termo "corrente descontaminada" se refere à corrente que fluiria através do canal da descarga caso os coeficientes de reflexão no topo e na base do objeto fossem iguais a zero. Neste trabalho, por meio de uma ferramenta computacional desenvolvida, diversos aspectos relacionados aos processos de “contaminação" e “descontaminação" de correntes são discutidos, com especial atenção no que se refere às influências dos vários parâmetros do sistema "canal-objeto-aterramento" no comportamento espaço-temporal da corrente. É também apresentada uma discussão acerca das características de uma corrente de descarga medida na base de uma torre de 62,5 m de altura localizada no Instituto de Eletrotécnica e Energia da Universidade de São Paulo.
Titre en anglais
Lightning current discharge evaluation through direct measure in tall towers
Mots-clés en anglais
elevated objects
lightning
return stroke models
“contaminated” current
Resumé en anglais
The characteristics of lightning currents have a fundamental importance on insulation coordination and on the design of transmission and distribution lines equipment. The CIGRE cumulative frequency distribution curves relative to the main parameters of the first and subsequent downward flashes, which are very frequently used for the evaluation of the lightning performance of transmission and distribution lines, refers to data obtained from negative current measurements from tall instrumented structures. However, currents measured on elevated objects may present distortions associated with differences on the impedances of the lightning channel, the strike object and the grounding system. In other words, the current in such objects may, in some circumstances, depend significantly on the measuring point and differ substantially from the current that flows along the lightning channel. These currents are called "contaminated". The curves regarding current magnitudes, front times and rates of rise presented in CIGRE refer to these "contaminated" currents, since the reflections that occur at the base and at the top of elevated strike objects were not taken into account in the processing of the data that led to those curves. The data should, thus, be reviewed. On the other hand, the term “decontaminated" current stands for the current that flows through the lightning channel assuming reflection coefficients at the bottom and at the top of the strike object equal to zero, i.e., the same impedances for the lightning channel, the elevated object and the grounding system. In this work a computer code was developed and several aspects related to the "contamination" and "decontamination" processes are discussed, with emphasis upon the influences of the various parameters of the system "lightning channel - strike object - grounding" on the stroke current. A discussion of the characteristics of a stroke current measured at the bottom of a 62,5 m high mast located at the Instituto de Eletrotécnica e Energia da Universidade de São Paulo is also presented.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2006-02-02
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.