• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.85.2011.tde-31102011-102809
Documento
Autor
Nombre completo
Melissa Santos Folgosi Corrêa
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2011
Director
Tribunal
Nogueira, Gessé Eduardo Calvo (Presidente)
Ana, Patricia Aparecida da
Daghastanli, Nasser Ali
Soares, Carlos Roberto Jorge
Spencer, Patrick Jack
Título en portugués
Caracterização das flutuações do sinal laser doppller do fluxo  microvascular
Palabras clave en portugués
fluxo sanguineo cutâneo
fluxometria laser Doppler
vasomotilidade
Resumen en portugués
O sinal de fluxo cutâneo obtido via fluxometria Laser Doppler (SFLD) tem flutuações de baixas frequências que estão relacionadas a mecanismos de controle do fluxo microvascular. Análises espectrais, via transformada de Fourier e transformada de wavelet, têm sido usadas para correlacionar as flutuações de SFLD com os seguintes mecanismos de controle de fluxo: metabólico, metabólico NO-dependente, neurogênico e miogênico, nos respectivos intervalos de frequência 0,005-0,0095 Hz, 0,0095-0,02 Hz, 0,02-0,05 Hz e 0,05-0,15 Hz. A potência do sinal, em cada intervalo de frequência, geralmente é usada como uma medida da atividade do mecanismo de controle microvascular relacionado. Uma vez que os métodos usados de análise são espectrais, as características das flutuações do SFLD, em cada intervalo de frequência, no domínio do tempo são desconhecidas. Como consequência, há ausência de critérios objetivos para medir adequadamente, em cada intervalo de frequência, os parâmetros hemodinâmicos relacionados. O objetivo deste trabalho foi caracterizar e quantificar flutuações temporais, espaciais e espaço-temporais do SFLD em cada faixa de frequência, usando um método no domínio do tempo. Os fluxos basais (320C) e termicamente estimulados à (420C) das regiões volares de antebraços de 20 voluntários saudáveis foram coletados em duas regiões próximas e analisados. As análises dos dados obtidos indicam que janelas temporais pequenas (1 minuto) são aceitáveis para a quantificação do fluxo médio, e que janelas temporais maiores são necessários para quantificar as flutuações de fluxo. A análise espaço-temporal revelou uma forte correlação entre sinais (em todas as bandas, exceto na banda B5) das duas regiões investigadas, durante longos intervalos de tempo, quando as duas regiões estudadas foram termicamente estimuladas, e menor variabilidade intragrupo quando comparada à obtida para os valores médios das flutuações, sugerindo que o intervalo de tempo de correlação é um parâmetro promissor para estudar mecanismos de controle do fluxo microvascular.
Título en inglés
Characterization of laser Doppler signal fluctuations in microvascular flow
Palabras clave en inglés
laser Doppler flowmeter
skin blood flow
vasomotion
Resumen en inglés
The laser Doppler flow signal from the skin (LDFS) has low-frequency fluctuations which are related to microvascular mechanisms of flow control. The Fourier and the wavelet spectral analysis has been used to correlate fluctuations in the LDFS with the metabolic, metabolic NO-dependent, neurogenic and myogenic mechanisms of control in the frequency intervals 0.005-0.0095 Hz, 0.0095-0.02 Hz, 0.02-0.05 Hz and 0.05-0.15 Hz, respectively. The signal power, in each frequency interval, is generally used as a measure of the activity of the related mechanism of microvascular control. Since spectral analysis methods have been used, the time-domain characteristics of the fluctuations in the LDFS in each frequency interval are unknown. As a consequence, there is a lack of objective criteria to properly measure, in each frequency interval, the related hemodynamic parameters. The aim of this work was characterizing and quantifying temporal, spatial and spatial-temporal fluctuations in the LDFS in each frequency band, using a time-domain method. Baseline (320C) and thermally stimulated (420C) LDFS of volar forearms from 20 healthy volunteers were collected from two close regions and analyzed. The data obtained indicate that short-time windows (1 minute) are acceptable for quantifying the mean flow, and that larger time-windows are needed for quantifying the flow fluctuations. The spatialtemporal analysis revealed strong correlations between signals (all bands, except B5) from the two investigated regions, during large time intervals when thermally stimulated, and lower intragroup variability than the ones obtained for the mean values of fluctuations, suggesting that the time interval of correlation is a promising parameter for studying mechanisms of microvascular flow control.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2011-12-14
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.