• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2006.tde-31052007-142823
Documento
Autor
Nombre completo
Peterson Porto
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2006
Director
Tribunal
Bustillos, José Oscar Willian Vega (Presidente)
Brito, Hermi Felinto de
Buchmann, José Henrique
Título en portugués
"Otimização da análise isotópica de UF6 utilizando-se a técnica de espectrometria de massas por quadrupolo"
Palabras clave en portugués
análise isotópica
espectrometria de massas
hexfluoreto de urânio
Resumen en portugués
Neste trabalho foi estabelecido um procedimento para determinação da razão isotópica 238U/235U em amostras de UF6, utilizando-se um espectrômetro de massas quadrupolar com ionização por impacto eletrônico e detecção de íons por copo de Faraday ou multiplicador de elétrons. Para tanto, o espectrômetro foi otimizado, determinando-se os parâmetros para a fonte de íons que proporcionassem a maior intensidade de corrente iônica, mantendo o pico de forma arredondada, para a massa correspondente ao isótopo mais abundante; a resolução que reduzisse os efeitos não lineares e o número de ciclos analíticos que reduzisse a incerteza nos resultados. O processo de medição foi caracterizado quanto: aos efeitos de discriminação de massa, linearidade e efeito memória. A discriminação de massas mostrou ser linearmente dependente da pressão da amostra no tanque de expansão nas faixas de 0,15 a 0,30 mbar e de 0,30 a 0,40 mbar. O espectrômetro mostrou-se linear na medição de razões isotópicas entre 0,005 e 0,045. Os fatores de memória para a fonte de íons e para o sistema de introdução são, respectivamente, 1,000 ± 0,001 e 1,003 ± 0,003; o primeiro pode ser desprezado e o segundo eliminado por procedimentos de lavagem do sistema de introdução. O trabalho apresenta, em sua parte final, um roteiro para as análises de amostras de UF6 e a determinação das incertezas nos resultados.
Título en inglés
OPTIMIZATION OF THE ISOTOPIC ANALYSIS OF UF6 BY QUADRUPOLE MASS SPECTROMETRY TECHNIC
Palabras clave en inglés
Hexfluoreto of Uranian
isotopic analysis
mass spectrometry
Resumen en inglés
In the present work a procedure for determination of the isotopic ratio 238U/235U in UF6 samples was established using a quadrupole mass spectrometer with ionization by electron impact and ion detection by Faraday cup or electron multiplier. For this, the following items were optimized in the spectrometer: the parameters in the íon source that provided the most intense peak, with good shape, for the corresponding mass of the most abundant isotope; the resolution that reduced the non linear effects and the number of analytic cycles that reduced the uncertainty in the results. The measurement process was characterized with respect to the effects of mass discrimination, linearity and memory effect. The mass discrimination showed to be linearly dependent of the sample pressure in the batch volume, for the pressure ranges from 0.15 to 0.30 mbar and from 0.30 to 0.40 mbar. The spectrometer was shown linear in the measurement of isotopic ratios between 0.005 and 0.045. The memory factor for the íon source and for the introduction system were, respectively, 1.000 ± 0.001 and 1.003 ± 0.003; the first one can be ignored, the second one can be eliminated by washing the batch volume with the new sample. A methodology for routine analysis of UF6 samples and the determination of the uncertainties were set up in details as well.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
PetersonPorto.pdf (1.19 Mbytes)
Fecha de Publicación
2007-06-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.