Doctoral Thesis
DOI
https://doi.org/10.11606/T.85.2014.tde-29092015-083645
Document
Author
Full name
Luís Cláudio Aranha
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2014
Supervisor
Committee
Rossi, Jesualdo Luiz (President)
Bonachela, Wellington Cardoso
Braga, Francisco Jose Correa
Casemiro, Luciana Assirati
Mucsi, Cristiano Stefano
Title in Portuguese
Estudo dos parâmetros de estabilidade de travamento entre implante dentário e componente protético através do sistema cone Morse
Keywords in Portuguese
cone Morse
contaminação
fadiga
implante
microtorque
Abstract in Portuguese
Na implantodontia visa-se dois grandes resultados para os desdentados parciais e totais, função mastigatória e estética. Ambos têm o mesmo grau de importância, para tanto se deve pensar no que se tem de mais seguro e prático nos dias de hoje. O cone Morse, na implantodontia oral, é um sistema de estabilidade entre o implante dentário e o parafuso intraósseo de sustentação. Para seu correto uso se faz necessário uma série de análise de suas características e condições. No presente trabalho focou-se em desenvolver protocolo de validação de torque, além de analisar parâmetros de acabamento, deformação e estabilidade précarga e pós-carga dentro de protocolos já recomendados. Avaliou-se sua condição antes e após os efeitos de carga mastigatória simulada por ensaio de fadiga. Concluiu-se que o uso do cone Morse dentro dos protocolos indicados deve ser revisto quanto a padrões similares de torque nos pilares sólidos e indexados, cada um possui limites e indicações diferentes para se manter estável. Concluiu-se também que não é um sistema totalmente livre de trânsito de bactérias e que esse trânsito aumenta de forma proporcional ao uso e força mastigatória, indicando que melhorias no acabamento entre as peças devem ser implementadas e/ou adição de material que afaste crescimento bacteriano priorizando a saúde do periodonto e do tecido ósseo de sustentação mantendo o sistema seguro em longevidade.
Title in English
Study on the stability parameters of locking between dental implants and prosthetic component system through the Morse taper
Keywords in English
contamination
fatigue
implant
microtorque
Morse taper
Abstract in English
In implantology it is aimed two major outcomes for the partial and total toothless persons, mastigatory function and aesthetics. Both have the same degree of importance, therefore it must be thought about what is safer and more practical these days. Morse taper in oral implantology is a system of stability between the dental implant and the intraosseous screw support. For its correct use a series of analysis of its features and conditions is required. This work was focused on developing torque validation protocol, and analyzing surface finishing parameters, deformation and stability as before load and after load in recommended protocols. The implants condition before and after the effects of habitual masticatory load was simulated by fatigue testing. It was concluded that the Morse taper use within the specified protocols should be reviewed for similar patterns of torque in solids and indexed pillars, each has different limits and signs to remain stable. It was also concluded that it is not a traffic totally free system of bacteria and that this influence increases in proportion to the use and masticatory forces, improvements in the surface finish between parts and / or addition of material that hinders bacterial growth is needed if it is prioritized the health of the periodontium and the bone tissue keeping the system safe in the long therm.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
2014AranhaEstudo.pdf (3.42 Mbytes)
Publishing Date
2015-10-09
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.