• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.85.2006.tde-29052007-151318
Document
Author
Full name
Júlio Takehiro Marumo
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2006
Supervisor
Committee
Lima, Luis Filipe Carvalho Pedroso de (President)
Boscov, Maria Eugenia Gimenez
Flues, Marlene Sotto Mayor
Hiromoto, Goro
Teixeira, Egle Novaes
Title in Portuguese
"Avaliação da contaminação provocada por pará-raios radioativos de Amerício-241 descartados em lixões"
Keywords in Portuguese
americio 241
para raios
rejeito radioativo
Abstract in Portuguese
Os pára-raios radioativos foram fabricados no Brasil até 1989, quando a Comissão Nacional de Energia Nuclear (CNEN) suspendeu a concessão de uso de material radioativo nesses artefatos. Desde então, o pára-raios radioativo tem sido substituído por outro, do tipo Franklin, e recolhido como rejeito radioativo. Entretanto, apenas 23 % do total fabricado no país foram entregues à CNEN. Esta situação é preocupante, pois a chance, desses artefatos serem descartados como resíduo comum e chegarem a lixões, é grande, uma vez que, segundo dados do Instituto Brasileiro de Geografia e Estatística (IBGE), em 2000, 63,6 % dos municípios brasileiros dispunham o resíduo nesses locais. Além disso, o amerício, o radionuclídeo mais empregado, é classificado como sendo um elemento de alta toxicidade, quando ingerido ou inalado. No presente trabalho, foram realizados experimentos de migração de Am-241 em lisímetros, com o objetivo de se avaliar o risco de contaminação provocada por pára-raios radioativos descartados como resíduo comum. Fontes radioativas removidas de pára-raios foram inseridas em lisímetros preenchidos com resíduo orgânico, coletado no restaurante do Instituto de Pesquisas Energéticas e Nucleares, IPEN-CNEN/SP, e chorume gerado foi periodicamente analisado para determinar suas características como pH, potencial redox, teor de sólidos e a concentração do material radioativo. O crescimento microbiano também foi avaliado, pelo método de contagem direta do número de unidades formadoras de colônia. A estimativa de risco foi baseada no cálculo de dose para membros do público, sendo a ingestão de água a via mais provável de exposição. O valor obtido foi cerca de 1000 vezes inferior ao limite de dose anual estabelecido, pela Comissão Internacional de Proteção Radiológica (ICRP), demonstrando que o risco de contaminação provocado pelo descarte de pára-raios em lixões é baixo.
Title in English
EVALUATION OF THE CONTAMINATION RISK BY 241AM FROM LIGHTNING RODS DISPOSED AT UNCONTROLLED GARBAGE DUMP
Keywords in English
americium 241
lightning rods
radioactive waste
Abstract in English
Radioactive lightning rods were manufactured in Brazil until 1989, when the licenses for using radioactive sources in these products were lifted by the national nuclear authority. Since then, radioactive devices have been replaced by Franklin type one and collected as radioactive waste. However, only 23 percent of the estimated total number of installed rods was delivered to Brazilian Nuclear Commission (Comissão Nacional de Energia Nuclear – CNEN). This situation is of concern to us as there is a possibility of the rods being discarded as domestic waste, considering that in Brazil, 63.6 percent of the municipal solid waste is disposed at uncontrolled garbage dump, according to Instituto Brasileiro de Geografia e Estatística (IBGE) in 2000. In addition, americium, the most common employed radionuclide, is classified as a high toxicity element, when ingested or inhaled. In the present study, it was performed migration experiments of Am-241 by lysimeter system in order to evaluate the risk of contamination caused by radioactive lightning rods disposed as a common solid waste. Sources removed from lightning rods were placed inside lysimeters filled with organic waste, collected at the restaurant of Instituto de Pesquisas Energéticas e Nucleares, IPEN-CNEN/SP, and the generated leachate was periodically analyzed to determine its characteristics such as pH, redox potential, solid content and concentration of the radioactive material. Microbial growth was also evaluated by counting the number of colony forming units. The equivalent dose to members of the public has been calculated considering the ingestion of drinking water, the most probable mode of exposure. The final result was about 145 times below the effective dose limit of 1 mSv.year-1 for members of the public, established by the International Commission on Radiological Protection (ICRP), demonstrating that the risk caused by lightning rods disposed at uncontrolled garbage dump is low.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
JulioMarumo.pdf (4.18 Mbytes)
Publishing Date
2007-06-22
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.