• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.85.2012.tde-23102012-144705
Document
Auteur
Nom complet
Leandro Matiolli Machado
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2012
Directeur
Jury
Rossi, Wagner de (Président)
Carreno, Marcelo Nelson Paez
Riva, Rudimar
Samad, Ricardo Elgul
Wetter, Niklaus Ursus
Titre en portugais
Microusinagem de dielétricos com pulsos laser de femtossegundos
Mots-clés en portugais
D-Scan
femtossegundos
laser
Limiar de Dano
microusinagem
Resumé en portugais
Neste trabalho foi utilizado o método de regressão do diâmetro para a medida do limiar de ablação nos materiais Suprasil, BK7, Safira e Ti:Safira por pulsos de femtossegundos. Através de medidas dos limiares de ablação para pulsos únicos e pulsos sobrepostos, quantificou-se o parâmetro de incubação para cada dielétrico. Essas medidas preliminares serviram para validação do método denominado Diagonal Scan ou D-scan. Para tanto, o método D-scan teve seu formalismo expandido o que possibilitou a quantificação da sobreposição de pulsos durante o seu uso. A simplicidade e rapidez do método D-scan permitiram que o limiar de ablação no BK7 fosse medido para diferentes larguras temporais e sobreposições. O limiar de ablação para pulsos únicos em função da largura temporal dos pulsos foi comparado com uma simulação teórica. A partir do conhecimento do parâmetro de incubação desenvolveu-se uma metodologia de usinagem em dielétricos que considera a sobreposição de pulsos durante a ablação. Isso permitiu a fabricação de microcanais para uso em microfluídica em BK7.
Titre en anglais
Micromachining of dieletrics with femtosecond laser pulses
Mots-clés en anglais
D-Scan
Damage Threshold
femtosecond
laser
micromaching
Resumé en anglais
In this study, the diameter regression method was used to measure the ablation threshold of Suprasil, BK7, Sapphire and Ti: Sapphire by femtosecond pulses. Through measurements of the ablation thresholds for single and overlapping pulses, the incubation parameter for each dielectric was quantified. These preliminary steps were used to validate the method called Diagonal Scan or D-scan. This was made possible by expanding the D-scan formalism, which allowed the quantification of overlapping pulses during its use. The simplicity of the D-scan method allowed the ablation threshold measurement in BK7 for different temporal widths and overlaps. The ablation threshold for single pulse for different temporal width was compared with a theoretical simulation. From the knowledge of the parameter of incubation, a methodology that considers dielectric machining overlapping pulses during ablation was developed. This allowed the manufacture of microchannels on BK7 for microfluidics.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2012-11-09
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.