• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2018.tde-23022018-094649
Documento
Autor
Nombre completo
Camila Fernanda Rocha Teles Tanzillo Santos
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2017
Director
Tribunal
Pires, Maria Aparecida Faustino (Presidente)
Fornaro, Adalgiza
Pedreira Filho, Walter dos Reis
Título en portugués
Análise de significância e caracterização de fontes estacionárias individualizadas visando o monitoramento atmosférico não radiológico no campus IPEN/CNEN-SP
Palabras clave en portugués
AP- 42
desenvolvimento e inovação
emissão de poluentes atmosféricos
estimativa de emissões
institutos de pesquisa
inventário
Resumen en portugués
Devido ao compromisso com a melhoria do meio ambiente, aliado às crescentes exigências dos órgãos ambientais, e a necessidade de identificar a contribuição de cada atividade/processo desenvolvido em institutos de pesquisas, quanto ao impacto destes à qualidade do ar, este trabalho teve a finalidade de desenvolver um modelo de inventário e aplicar uma metodologia de cálculo, que permita estimar a emissão de poluentes atmosféricos, decorrentes das atividades dos centros de pesquisa e desenvolvimento do Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP). O estudo foi motivado pela ausência de metodologias de cálculo de emissões atmosféricas específicas para fontes fixas como capelas químicas de exaustão e da necessidade em atender as condicionantes estabelecidas no licenciamento ambiental da instituição. Para a elaboração dos cálculos foram adotados os fatores de emissão e a equação descrita na AP-42 da EPA- Environmental Protection Agency. Foram utilizadas como abordagens de cálculo de emissões: a) Mensuração direta (por meio do inventário de emissões atmosféricas); e b) Estimativa de emissões (utilizando estimativa da taxa de emissão calculada a partir do fator de emissão apropriado). O estudo foi detalhadamente realizado tendo como base inicial o inventário e o modelo de estimativa de emissão atmosférica das fontes fixas aplicado no Centro de Química e Meio Ambiente (CQMA). Cabe ressaltar que o monitoramento online da qualidade do ar no campus é realizado em estação fixa, parceria IPEN CETESB, na estação CETESB Cid. Universitária IPEN - USP. O estudo possibilitou estabelecer, de forma efetiva, o Programa de Monitoramento e Controle de Emissões Atmosféricas (PMEA IPEN), podendo servir de modelo para outras instituições de Pesquisa, Desenvolvimento & Inovação. Como produto final obteve-se um inventário de emissões atmosféricas de fontes fixas da instituição, a taxa de emissão de poluentes, bem como a concentração de poluentes emitidos. A estimativa das emissões não ultrapassou os limites dispostos na legislação em âmbito nacional e estadual.
Título en inglés
Analysis of significance and characterization of individualized stationary sources for non-radiological atmospheric monitoring at campus of IPEN / CNEN-SP
Palabras clave en inglés
AP-42
development and innovation institutions
emission of atmospheric pollutants
emissions estimate
inventory
research
Resumen en inglés
Atmospheric Emission Factors and Significance Analysis applied to the Air Quality Management in the IPEN / CNEN-SP Campus due to the commitment to improve the environment, combined with the increasing demands of environmental agencies, and the need to identify the contribution of each activity / process developed in research institutes, as well as the impact of these on the air quality, this work aims to develop an inventory model and apply a methodology of calculation for measuring the emission of atmospheric pollutants, arising from the activities of the research and development centers of the Nuclear and Energy Research Institute (IPEN / CNEN-SP). The study was motivated by the absence of atmospheric emission calculation methodologies specific to stationary sources, such as fume hoods. For preparation of the calculations, the emission factors and the equation described in the AP-42 EPA- Environmental Protection Agency were adopted. The emission calculation methods used were: a) Direct measurement (through the inventory of air emissions); and b) Emissions estimate (using the emission rate estimate calculated from the appropriate emission factor). The study was carried out in detail, based on the inventory and model of atmospheric emission of fixed sources applied at the Chemistry and Environment Center (CQMA). It should be noted that online monitoring of air quality on campus is carried out at a fixed station, IPEN CETESB partnership, at CETESB Cid station. University - IPEN - USP. The study has made it possible to establish, in an effective way, the Atmospheric Emission Monitoring and Control Program (PMEA - IPEN), which could serve as a model for other Research, Development and Innovation institutions. The final product was an inventory of atmospheric emissions from fixed sources of the institution, the emission rate of pollutants, as well as the concentration of pollutants emitted. The estimation of the emissions did not exceed the limits established in the national legislation and state level.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
2017SantosAnalise.pdf (3.09 Mbytes)
Fecha de Publicación
2018-03-01
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.