• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.85.2014.tde-22012015-104509
Document
Author
Full name
Diogenes Cordeiro de Souza Neto
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2014
Supervisor
Committee
Monteiro, Waldemar Alfredo (President)
Neves, Maurício David Martins das
Vatavuk, Jan
Title in Portuguese
Caracterização microestrutural e mecânica de uma liga de Co-Cr. Uma avaliação de seu desempenho mecânico em um produto de engenharia
Keywords in Portuguese
biomateriais
cobalto
cromo
stent
superliga
Abstract in Portuguese
Este estudo foi desenvolvido no Instituto de Pesquisas Energéticas e Nucleares IPEN mais especificamente, no Centro de Ciência e Tecnologia dos Materiais CCTM com apoio da empresa Innovatech. Foram estudados tubos de Co-Cr (L605) usados para fabricação de stents coronarianos, aplicação esta que pede um comportamento mecânico específico e biocompatibilidade. Os tubos de CoCr (L605) podem ser adquiridos em duas condições de história térmica: Trabalhado a frio ou com encruamento ou recozido. O tubo recozido se não estiver em condições para a aplicação, dificilmente será possível atingi-las com um novo tratamento térmico. O tubo encruado abre possibilidades para acertar as condições de tratamento térmico e obter a condição ideal de comportamento mecânico, sem comprometer outros aspectos importantes para a aplicação como biocompatibilidade. Foi selecionado um tubo de CoCr (L605) encruado e com uma quantidade grande de precipitados para os testes, foram selecionadas três faixas de temperatura para o tratamento térmico de recozimento uma abaixo do ponto de solubilização (1000°C), uma dentro da temperatura (1175°C) e uma terceira, mais próxima do ponto de fusão alcançável pelo forno (1250°C). Em cada temperatura foram usados quatro períodos de exposição ao forno( 4, 7, 10 e 15 minutos) totalizando uma matriz com 12 condições de tratamento térmico. Em cada tratamento térmico foram incluídas amostras para ensaio de tração e metalografia. O objetivo deste trabalho é estudar os efeitos dos tratamentos térmicos no comportamento mecânico e na microestrutura do material afim de levantar critérios para determinar os melhores parâmetros de tratamento térmico para a aplicação.
Title in English
Microstructural and mechanical characterization of a Co-Cr alloy. An evaluation of its mechanical performance in a product of engineering
Keywords in English
biomaterials
chromium
cobalt
stent
superalloy
Abstract in English
This study was developed at IPEN Institute of Energy and Nuclear Research more specifically in CCTM Materials Cience and Tecnology Center, with support of Innovatech Medical. It was studied Co-Cr (L605) tubes used for manufacture of coronary stents, this application require a specific mechanical behavior and biocompatibility. The tubes CoCr (L605) can be acquired in two conditions of thermal history: Cold worked or annealed. If the annealed tube doesn´t have the conditions for the application it is hardly possible to reach them with a new heat treatment. Hardened tube opens up more possibilities to adjust the conditions of thermal treatment and obtain the optimum condition of mechanical behavior without compromising other aspects important for application as biocompatibility. A tube CoCr (L605) Hardened and a relatively large amount of precipitates were selected for the tests, three temperature tracks have been selected for the thermal annealing treatment: below the temperature of solution aneealing(1000 ° C), at solution aneealing(1175 ° C) and a third temperature closest achievable by furnace (1250 ° C). For each temperature four periods of exposure where selected (4, 7, 10 and 15 minutes) totaling a matrix of 12 heat treatment conditions. In each heat treatment, samples for tensile testing and metallography were included. The objective of this work is to study the effects of heat treatment on mechanical behavior and microstructure of the material in order to raise criteria to determine the best heat treatment for the application.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2015-01-23
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.