Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.85.2014.tde-22012015-104509
Document
Auteur
Nom complet
Diogenes Cordeiro de Souza Neto
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2014
Directeur
Jury
Monteiro, Waldemar Alfredo (Président)
Neves, Maurício David Martins das
Vatavuk, Jan
Titre en portugais
Caracterização microestrutural e mecânica de uma liga de Co-Cr. Uma avaliação de seu desempenho mecânico em um produto de engenharia
Mots-clés en portugais
biomateriais
cobalto
cromo
stent
superliga
Resumé en portugais
Este estudo foi desenvolvido no Instituto de Pesquisas Energéticas e Nucleares IPEN mais especificamente, no Centro de Ciência e Tecnologia dos Materiais CCTM com apoio da empresa Innovatech. Foram estudados tubos de Co-Cr (L605) usados para fabricação de stents coronarianos, aplicação esta que pede um comportamento mecânico específico e biocompatibilidade. Os tubos de CoCr (L605) podem ser adquiridos em duas condições de história térmica: Trabalhado a frio ou com encruamento ou recozido. O tubo recozido se não estiver em condições para a aplicação, dificilmente será possível atingi-las com um novo tratamento térmico. O tubo encruado abre possibilidades para acertar as condições de tratamento térmico e obter a condição ideal de comportamento mecânico, sem comprometer outros aspectos importantes para a aplicação como biocompatibilidade. Foi selecionado um tubo de CoCr (L605) encruado e com uma quantidade grande de precipitados para os testes, foram selecionadas três faixas de temperatura para o tratamento térmico de recozimento uma abaixo do ponto de solubilização (1000°C), uma dentro da temperatura (1175°C) e uma terceira, mais próxima do ponto de fusão alcançável pelo forno (1250°C). Em cada temperatura foram usados quatro períodos de exposição ao forno( 4, 7, 10 e 15 minutos) totalizando uma matriz com 12 condições de tratamento térmico. Em cada tratamento térmico foram incluídas amostras para ensaio de tração e metalografia. O objetivo deste trabalho é estudar os efeitos dos tratamentos térmicos no comportamento mecânico e na microestrutura do material afim de levantar critérios para determinar os melhores parâmetros de tratamento térmico para a aplicação.
Titre en anglais
Microstructural and mechanical characterization of a Co-Cr alloy. An evaluation of its mechanical performance in a product of engineering
Mots-clés en anglais
biomaterials
chromium
cobalt
stent
superalloy
Resumé en anglais
This study was developed at IPEN Institute of Energy and Nuclear Research more specifically in CCTM Materials Cience and Tecnology Center, with support of Innovatech Medical. It was studied Co-Cr (L605) tubes used for manufacture of coronary stents, this application require a specific mechanical behavior and biocompatibility. The tubes CoCr (L605) can be acquired in two conditions of thermal history: Cold worked or annealed. If the annealed tube doesn´t have the conditions for the application it is hardly possible to reach them with a new heat treatment. Hardened tube opens up more possibilities to adjust the conditions of thermal treatment and obtain the optimum condition of mechanical behavior without compromising other aspects important for application as biocompatibility. A tube CoCr (L605) Hardened and a relatively large amount of precipitates were selected for the tests, three temperature tracks have been selected for the thermal annealing treatment: below the temperature of solution aneealing(1000 ° C), at solution aneealing(1175 ° C) and a third temperature closest achievable by furnace (1250 ° C). For each temperature four periods of exposure where selected (4, 7, 10 and 15 minutes) totaling a matrix of 12 heat treatment conditions. In each heat treatment, samples for tensile testing and metallography were included. The objective of this work is to study the effects of heat treatment on mechanical behavior and microstructure of the material in order to raise criteria to determine the best heat treatment for the application.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-01-23
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.