• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.85.2011.tde-21112011-095420
Document
Author
Full name
Leticia Lopes de Souza
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2011
Supervisor
Committee
Forbicini, Christina Aparecida Leão Guedes de Oliveira (President)
Falleiros, Neusa Alonso
Oliveira Neto, Almir
Title in Portuguese
Uso da voltametria cíclica e da espectroscopia de impedância eletroquímica na determinação da área superficial ativa de eletrodos modificados à base de carbono
Keywords in Portuguese
área superficial
eletrodos de carbono
espectroscopia de impedância eletroquímica
voltametria cíclica
Abstract in Portuguese
Eletrodos à base de carbono, como os eletrodos de troca iônica, entre outros, têm aplicação principalmente no tratamento de efluentes industriais e rejeitos radioativos. Carbono é também amplamente utilizado em células a combustível como substrato para os eletrocatalisadores, por possuir elevada área superficial, que supera a sua área geométrica. O conhecimento desta superfície ativa total é importante na determinação das condições de operação de uma célula eletroquímica no que diz respeito às correntes a serem aplicadas (densidade de corrente). No presente estudo foram utilizadas duas técnicas eletroquímicas na determinação da área superficial ativa de eletrodos de carbono vítreo e poroso e eletrodos de troca iônica: espectroscopia de impedância eletroquímica (EIE) e voltametria cíclica (VC). Os experimentos foram realizados com soluções de KNO3 0,1 mol.L-1 em célula eletroquímica de três eletrodos: eletrodo de trabalho à base de carbono, eletrodo auxiliar de platina e eletrodo de referência de Ag/AgCl. Os eletrodos de carbono vítreo e de carbono poroso utilizado possuíam uma área geométrica de 3,14 x 10-2 cm2 e 2,83 10-1 cm2, respectivamente. O eletrodo de troca iônica foi preparado misturando-se grafite, carbono, resina de troca iônica e um aglutinante, sendo esta mistura aplicada em três camadas sobre feltro de carbono, utilizando-se nos experimentos uma área geométrica de 1,0 cm2. Por EIE determinou-se diretamente a capacitância dos materiais dos eletrodos (Cd) utilizando-se os diagramas de Bode. O valor de 172 μF.cm-2 encontrado para o carbono vítreo está de acordo com a literatura (~200 μF.cm-2). Por VC, variando a velocidade de varredura de 0,2 a 2,0 mV.s-1, determinou-se a capacitância CdS (S=área superficial ativa) na região da dupla camada elétrica (DCE) para cada um dos materiais, Por EIE, foram determinados os valores de Cd de 3,0 x 10-5 μF.cm-2 e de 11,0 x 103 μF.cm-2 para os eletrodos de carbono poroso e de troca iônica, respectivamente, o que possibilitou a determinação das áreas superficiais ativas de 3,73 x 106 cm2 e 4,72 cm2. Portanto, o uso combinado das técnicas de EIE e VC mostra-se promissor para o cálculo das áreas superficiais ativas de eletrodos à base de carbono.
Title in English
Use of cyclic voltammetry and electrochemical impedance spectroscopy for the determination of active surface area of modified carbon-based electrodes
Keywords in English
carbon electrodes
cyclic voltammetry
electrochemistry impedance spectroscopy
surface area
Abstract in English
Carbon-based electrodes as well the ion exchange electrodes among others have been applied mainly in the treatment of industrial effluents and radioactive wastes. Carbon is also used in fuel cells as substrate for the electrocatalysts, having high surface area which surpasses its geometric area. The knowledge of the total active area is important for the determination of operating conditions of an electrochemical cell with respect to the currents to be applied (current density). In this study it was used two techniques to determine the electrochemical active surface area of glassy carbon, electrodes and ion exchange electrodes: cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The experiments were carried out with KNO3 0.1 mol.L-1 solutions in a three-electrode electrochemical cell: carbon-based working electrode, platinum auxiliary electrode and Ag/AgCl reference electrode. The glassy carbon and porous carbon electrodes with geometric areas of 3.14 x 10-2 and 2.83 10-1 cm2, respectively, were used. The ion exchange electrode was prepared by mixing graphite, carbon, ion exchange resin and a binder, and this mixture was applied in three layers on carbon felt, using a geometric area of 1.0 cm2 during the experiments. The capacitance (Cd) of the materials was determined by EIS using Bode diagrams. The value of 172 μF.cm-2 found for the glassy carbon is consistent with the literature data (~200 μF.cm-2). By VC, varying the scan rate from 0.2 to 2.0 mV.s-1, the capacitance CdS (S = active surface area) in the region of the electric double layer (EDL) of each material was determined. By EIS, the values of Cd, 3.0 x 10-5 μF.cm-2 and 11 x 103 μF.cm-2, were found for the porous carbon and ion exchange electrodes, respectively, which allowed the determination of active surface areas as 3.73 x 106 cm2 and 4.72 cm2. To sum up, the combined use of EIS and CV techniques is a valuable tool for the calculation of active surface areas of carbon-based electrodes.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
2011SouzaUso.pdf (2.59 Mbytes)
Publishing Date
2011-12-14
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.