• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2013.tde-10012014-111938
Documento
Autor
Nombre completo
Marcelo Noronha Veloso
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2013
Director
Tribunal
Zezell, Denise Maria (Presidente)
Bachmann, Luciano
Santo, Ana Maria do Espirito
Título en portugués
Avaliação in vitro dos efeitos da radiação ionizante em tecido ósseo bovino por espectroscopia ATR-FTIR e análise dinâmico-mecânica
Palabras clave en portugués
análise dinâmica mecânica DMA
espectroscopia FTIR
módulo elástico
osso
radiação gama
Resumen en portugués
A radiação ionizante de fontes de radiação gama ou geradores de raios-x é frequentemente utilizada na ciência médica, como em exames de radiodiagnóstico, radioterapia e esterilização de aloenxertos. A radiação ionizante é capaz de quebrar cadeias polipeptidicas e provocar a libertação de radicais livres, pela radiólise de moléculas de água. A radiação ionizante interage também com o material orgânico a nível molecular, podendo alterar as suas propriedades mecânicas. No caso específico do tecido ósseo, estudos reportam que a radiação ionizante induz alterações nas moléculas de colágeno e reduzem a densidade de ligações cruzadas intermoleculares. O objetivo deste estudo foi verificar as alterações promovidas por diferentes doses de radiação ionizante no tecido ósseo utilizando a técnica de Espectroscopia Transformada de Fourier com Reflexão Total Atenuada (ATR-FTIR), e também a análise dinâmico-mecânica. Amostras de osso bovino foram irradiadas usando irradiador de Cobalto-60, com cinco doses diferentes: 0,01 kGy, 0,1 kGy, 1 kGy, 15 kGy e 75 kGy. Para estudar os efeitos da radiação ionizante sobre a estrutura química do osso foram avaliadas a relação material orgânico por material inorgânico, a relação de sub-bandas de amida I e o índice de cristalinidade. As alterações mecânicas foram determinadas por meio do módulo de elasticidade e do valor do amortecimento. Para verificar se as mudanças químicas e as características mecânicas de osso possuem alguma relação, realizou-se um estudo sobre a correlação entre as análises feitas com os dados espectroscópicos e as análises mecânicas. Foi possível avaliar os efeitos de diferentes doses de radiação ionizante no tecido ósseo. Com a análise por espectroscopia ATR-FTIR, foi possível observar as modificações dos componentes orgânicos e na organização cristais de hidroxiapatita. Também foram observadas alterações no módulo elástico e na tangente de delta (dissipação de energia mecânica). Foram encontradas altas correlações com significância estatística entre a relação das bandas (amida III + colágeno)/v1,v3, PO43- com a tangente de delta, e entre a relação 1/FHMW e o módulo elástico.
Título en inglés
In vitro evaluation of ionizing radiation effects in boné tissue by FTIR spectroscopy and dynamic mechanical analysis
Palabras clave en inglés
bone
dynamics mechanic analysis DMA
elastic modulus
FTIR spectroscopy
gama radiation
Resumen en inglés
Ionizing radiation from gamma radiation sources or X-ray generators is frequently used in Medical Science, such as radiodiagnostic exams, radiotherapy, and sterilization of haloenxerts. Ionizing radiation is capable of breaking polypeptidic chains and causing the release of free radicals by radiolisys.of water. It interacts also with organic material at the molecular level, and it may change its mechanical properties. In the specific case of bone tissue, studies report that ionizing radiation induces changes in collagen molecules and reduces the density of intermolecular crosslinks. The aim of this study was to verify the changes promoted by different doses of ionizing radiation in bone tissue using Fourier Transform Infrared Spectroscopy (FTIR) and dynamic mechanical analysis (DMA). Samples of bovine bone were irradiated using Cobalt-60 with five different doses: 0.01 kGy, 0.1 kGy, 1 kGy, 15 kGy and 75 kGy. To study the effects of ionizing irradiation on the chemical structure of the bone, the sub-bands of amide I, the crystallinity index and relation of organic and inorganic materials, were studied. The mechanical changes were evaluated using the elastic modulus and the damping value. To verify whether the chemical changes and the mechanical characteristics of the bone were correlated, the relation between the analysis made with spectroscopic data and the mechanical analysis data was studied. It was possible to evaluate the effects of different doses of ionizing radiation in bone tissue. With ATR-FTIR spectroscopy, it was possible to observe changes in the organic components and in the hidroxyapatite crystals organization. Changes were also observed in the elastic modulus and in the damping value. High correlation with statistical significance was observed among (amide III + collagen)/v1,v3, PO43- and the delta tangent, and among 1/FHWM and the elastic modulus.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-01-14
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.