• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.85.2012.tde-05112012-090907
Document
Author
Full name
Renan de Azevedo da Silva
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2012
Supervisor
Committee
Martins, Elâine Arantes Jardim (President)
Furusawa, Hélio Akira
Petroni, Sérgio Luis Graciano
Title in Portuguese
Desenvolvimento de software como ferramenta de confiabilidade para a análise da água subterrânea do IPEN
Keywords in Portuguese
compostos fenólicos
desenvolvimento de software
incerteza de medição
validação de método
Abstract in Portuguese
Neste estudo foi proposto o desenvolvimento de um software para automatizar o processo de estimativa da incerteza de medição pelo método descrito no Guia EURACHEM. Com a finalidade de testar a eficácia do software, foi desenvolvido um procedimento analítico para a determinação de compostos fenólicos na água subterrânea do Instituto de Pesquisas Energéticas e Nucleares a fim de se obter dados reais de um processo. Para tanto, a determinação dos compostos foi realizada por cromatografia gasosa acoplada ao detector de espectrometria de massas, GC/MS. Para garantir a qualidade dos dados gerados, o procedimento analítico foi submetido ao processo de validação, onde foram avaliados os parâmetros: seletividade/especificidade, faixa de trabalho e faixa linear de trabalho, linearidade, limite de detecção, limite de quantificação, precisão, exatidão, recuperação e robustez. A estimativa da incerteza da medição foi realizada pelo software desenvolvido e manualmente, confirmando que o mesmo é adequado para o processo. Além disso, o software foi testado utilizando dados da literatura, o que confirmou sua eficácia. Os resultados da análise da água subterrânea demonstraram que não há a presença de compostos fenólicos nos níveis estudados. A utilização de sistemas automatizados para a estimativa da incerteza diminui ou minimiza erros sistemáticos e permite trabalhar com mais organização e controle do processo.
Title in English
Software development as a tool for reliability analysis of groundwater of IPEN
Keywords in English
method validation
phenolic compounds
software development
uncertainty measurement
Abstract in English
A software development to automate the process of uncertainty measurement by the method described by the Guide EURACHEM is proposed. In order to test the effectiveness of the software, an analytical procedure for phenolic compounds determination in the ground water was developed. Water samples were collected at Instituto de Pesquisas Energéticas e Nucleares (IPEN, São Paulo, Brazil) campus area. The determination of compounds was performed by gas chromatography coupled to mass spectrometry detector (GC / MS). To ensure the quality of the generated data, the analytical procedure was submitted to a validation process. The evaluated parameters were: selectivity / specificity, working range and linear range, linearity, detection limit, quantification limit, precision, recovery and robustness. The uncertainty measurements were performed by the software and manually, confirming that it is suitable for the process. Moreover, the software was tested using literature data, which confirmed its effectiveness. The results of the ground water analysis showed that there are no phenolic compounds within the studied levels. The use of automated systems for the uncertainty estimation is very promising because it reduces or minimizes systematic errors and allows working in a more organized way and with the process under control.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2012-11-09
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.