Orientador
Banca examinadora
Silva, Antonio Teixeira e (Presidente)
Sabundjian, Gaianê
Souza, Gilberto Francisco Martha de
Título em português
Aplicação da técnica de análise de modos de falha e efeitos ao sistema de resfriamento de emergência de uma instalação nuclear experimental
Palavras-chave em português
AMFE
Análise de Risco
SRE
Resumo em português
Este trabalho consiste em aplicar a técnica de identificação de perigos e análise de risco conhecida como Análise de Modos de Falha e Efeitos (AMFE) ao Sistema de Resfriamento de Emergência (SRE) de uma instalação nuclear experimental, cuja função é a de mitigar as conseqüências de um eventual acidente de perda de refrigerante no circuito primário de um reator a água pressurizada. Esse tipo de análise tem como objetivo identificar as possíveis vulnerabilidades desse sistema e propor melhorias de modo a maximizar sua confiabilidade. Para isso foi realizado o estudo detalhado do sistema (por intermédio de sua documentação técnica), obtido o diagrama de blocos correspondente, feita a análise do tipo AMFE e, finalmente, apresentadas algumas sugestões.
Título em inglês
"Application of the failure modes and effects analysis technique to the emergency cooling system of an experimental nuclear power plant"
Palavras-chave em inglês
AMFE
Análise de Risco
SRE
Resumo em inglês
This study consists on the application of the Failure Modes and Effects Analysis (FMEA), a hazard identification and a risk assessment technique, to the Emergency Cooling System (ECS) of an experimental nuclear power plant, which is responsible for mitigating the consequences of an eventual loss of coolant accident on the Pressurized Water Reactor (PWR). Such analysis intends to identify possible weaknesses on the design of the system and propose some improvements in order to maximize its reliability. To achieve this goal a detailed study of the system was carried on (through its technical documentation), the correspondent reliability block diagram was obtained, the FMEA analysis was executed and, finally, some suggestions were presented.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2009-07-16
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.