Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.85.2009.tde-29062009-092542
Document
Auteur
Nom complet
Osmar Conceição Júnior
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2009
Directeur
Jury
Silva, Antonio Teixeira e (Président)
Sabundjian, Gaianê
Souza, Gilberto Francisco Martha de
Titre en portugais
Aplicação da técnica de análise de modos de falha e efeitos ao sistema de resfriamento de emergência de uma instalação nuclear experimental
Mots-clés en portugais
AMFE
Análise de Risco
SRE
Resumé en portugais
Este trabalho consiste em aplicar a técnica de identificação de perigos e análise de risco conhecida como Análise de Modos de Falha e Efeitos (AMFE) ao Sistema de Resfriamento de Emergência (SRE) de uma instalação nuclear experimental, cuja função é a de mitigar as conseqüências de um eventual acidente de perda de refrigerante no circuito primário de um reator a água pressurizada. Esse tipo de análise tem como objetivo identificar as possíveis vulnerabilidades desse sistema e propor melhorias de modo a maximizar sua confiabilidade. Para isso foi realizado o estudo detalhado do sistema (por intermédio de sua documentação técnica), obtido o diagrama de blocos correspondente, feita a análise do tipo AMFE e, finalmente, apresentadas algumas sugestões.
Titre en anglais
"Application of the failure modes and effects analysis technique to the emergency cooling system of an experimental nuclear power plant"
Mots-clés en anglais
AMFE
Análise de Risco
SRE
Resumé en anglais
This study consists on the application of the Failure Modes and Effects Analysis (FMEA), a hazard identification and a risk assessment technique, to the Emergency Cooling System (ECS) of an experimental nuclear power plant, which is responsible for mitigating the consequences of an eventual loss of coolant accident on the Pressurized Water Reactor (PWR). Such analysis intends to identify possible weaknesses on the design of the system and propose some improvements in order to maximize its reliability. To achieve this goal a detailed study of the system was carried on (through its technical documentation), the correspondent reliability block diagram was obtained, the FMEA analysis was executed and, finally, some suggestions were presented.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2009-07-16
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.