Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2009.tde-29062009-092542
Documento
Autor
Nombre completo
Osmar Conceição Júnior
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2009
Director
Tribunal
Silva, Antonio Teixeira e (Presidente)
Sabundjian, Gaianê
Souza, Gilberto Francisco Martha de
Título en portugués
Aplicação da técnica de análise de modos de falha e efeitos ao sistema de resfriamento de emergência de uma instalação nuclear experimental
Palabras clave en portugués
AMFE
Análise de Risco
SRE
Resumen en portugués
Este trabalho consiste em aplicar a técnica de identificação de perigos e análise de risco conhecida como Análise de Modos de Falha e Efeitos (AMFE) ao Sistema de Resfriamento de Emergência (SRE) de uma instalação nuclear experimental, cuja função é a de mitigar as conseqüências de um eventual acidente de perda de refrigerante no circuito primário de um reator a água pressurizada. Esse tipo de análise tem como objetivo identificar as possíveis vulnerabilidades desse sistema e propor melhorias de modo a maximizar sua confiabilidade. Para isso foi realizado o estudo detalhado do sistema (por intermédio de sua documentação técnica), obtido o diagrama de blocos correspondente, feita a análise do tipo AMFE e, finalmente, apresentadas algumas sugestões.
Título en inglés
"Application of the failure modes and effects analysis technique to the emergency cooling system of an experimental nuclear power plant"
Palabras clave en inglés
AMFE
Análise de Risco
SRE
Resumen en inglés
This study consists on the application of the Failure Modes and Effects Analysis (FMEA), a hazard identification and a risk assessment technique, to the Emergency Cooling System (ECS) of an experimental nuclear power plant, which is responsible for mitigating the consequences of an eventual loss of coolant accident on the Pressurized Water Reactor (PWR). Such analysis intends to identify possible weaknesses on the design of the system and propose some improvements in order to maximize its reliability. To achieve this goal a detailed study of the system was carried on (through its technical documentation), the correspondent reliability block diagram was obtained, the FMEA analysis was executed and, finally, some suggestions were presented.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2009-07-16
 