Master's Dissertation
DOI
https://doi.org/10.11606/D.85.2009.tde-29062009-092542
Document
Author
Full name
Osmar Conceição Júnior
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2009
Supervisor
Committee
Silva, Antonio Teixeira e (President)
Sabundjian, Gaianê
Souza, Gilberto Francisco Martha de
Title in Portuguese
Aplicação da técnica de análise de modos de falha e efeitos ao sistema de resfriamento de emergência de uma instalação nuclear experimental
Keywords in Portuguese
AMFE
Análise de Risco
SRE
Abstract in Portuguese
Este trabalho consiste em aplicar a técnica de identificação de perigos e análise de risco conhecida como Análise de Modos de Falha e Efeitos (AMFE) ao Sistema de Resfriamento de Emergência (SRE) de uma instalação nuclear experimental, cuja função é a de mitigar as conseqüências de um eventual acidente de perda de refrigerante no circuito primário de um reator a água pressurizada. Esse tipo de análise tem como objetivo identificar as possíveis vulnerabilidades desse sistema e propor melhorias de modo a maximizar sua confiabilidade. Para isso foi realizado o estudo detalhado do sistema (por intermédio de sua documentação técnica), obtido o diagrama de blocos correspondente, feita a análise do tipo AMFE e, finalmente, apresentadas algumas sugestões.
Title in English
"Application of the failure modes and effects analysis technique to the emergency cooling system of an experimental nuclear power plant"
Keywords in English
AMFE
Análise de Risco
SRE
Abstract in English
This study consists on the application of the Failure Modes and Effects Analysis (FMEA), a hazard identification and a risk assessment technique, to the Emergency Cooling System (ECS) of an experimental nuclear power plant, which is responsible for mitigating the consequences of an eventual loss of coolant accident on the Pressurized Water Reactor (PWR). Such analysis intends to identify possible weaknesses on the design of the system and propose some improvements in order to maximize its reliability. To achieve this goal a detailed study of the system was carried on (through its technical documentation), the correspondent reliability block diagram was obtained, the FMEA analysis was executed and, finally, some suggestions were presented.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2009-07-16
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.