Thèse de Doctorat
DOI
https://doi.org/10.11606/T.85.2018.tde-29012018-104857
Document
Auteur
Nom complet
Letícia Negrão Pinto
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2017
Directeur
Jury
Santos, Adimir dos (Président)
Carluccio, Thiago
Diniz, Ricardo
Lee, Seung Min
Rossi, Pedro Carlos Russo
Titre en portugais
Desenvolvimento de um reatímetro digital subcrítico baseado no modelo de cinética pontual de Gandini
Mots-clés en portugais
Gandini
IPEN/MB-01
reatímetro
reatividade
subcriticalidade
Resumé en portugais
Sistemas multiplicativos subcríticos foram, por muito tempo, pouco estudados, de modo que sua descrição teórica permanece com muitas questões em aberto. A presente Tese apresenta o um reatímetro subcrítico, um software desenvolvido em LabVIEWTM capaz de medir as mudanças no fluxo de nêutrons em regime subcrítico e de transformar este sinal em reatividade. A principal vantagem de um dispositivo como este é aumento da precisão das medidas de reatividade. É sabido que reatímetros convencionais não são capazes de operar em regime subcrítico nem de descrever a dinâmica de sistemas multiplicativos nessas condições, pela própria estrutura das equações de cinética pontual clássicas em que são baseados. Diversas teorias têm sido propostas para descrever a física de sistemas subcríticos, no entanto, a maior parte envolve parâmetros extremamente complexos para serem aplicados em situações práticas. A teoria de Gandini difere das outras por ser baseada em parâmetros simples, o que a torna a escolha mais conveniente para o desenvolvimento de um reatímetro subcrítico e suas aplicações. Desta maneira, o reatímetro subcrítico desenvolvido é baseado na teoria de cinética de sistemas subcríticos de Gandini e em resultados experimentais, de altíssima qualidade e relevância, alcançados no próprio IPEN/MB-01. Deve-se destacar que a aplicação de equações de cinética específicas para sistemas subcríticos é um fato inédito no desenvolvimento de reatímetros e apenas desta maneira a reatividade pode ser estimada com precisão neste regime. O presente estudo é especialmente focado na aplicação em reatores de fissão, o qual poderá se utilizado em inúmeros experimentos em reatores de pesquisa. Portanto, o presente trabalho tem relevância tanto teórica quanto prática, já que discute um ponto fundamental da física de reatores nucleares.
Titre en anglais
Development of a digital subcritical reactivity meter based on the Gandini's subcritical kinetic theory
Mots-clés en anglais
Gandini
IPEN/MB-01
reactivity
reactivity meter
subcriticality
Resumé en anglais
Multiplying subcritical systems were for a long time, poorly studied, and its theoretical description remains with plenty open questions. This Thesis presents a subcritical reactivity meter, a software developed in LabVIEWTM capable of measuring changes in neutron flux in subcritical regime and to transform this signal into reactivity. The main advantage of such device is the increase in accuracy of reactivity measurements. It is known that conventional reactivity meters cannot operate in subcritical regime nor describe the dynamics of multiplying systems under these conditions by the very structure of classical point kinetics equations. Many theories have been proposed to describe subcritical systems but most involve very complex parameters to be applied in practical situations. Gandini's theory differs from others by being based on simple parameters, being considered the most convenient choice to be made for the development of a reactivity meter and its applications. The developed subcritical reactivity meter was based on the Gandini's subcritical kinetic theory and on experimental results, of high quality and relevance, achieved at the IPEN/MB-01 reactor. It should be highlighted that the utilization of specific kinetic equations for subcritical systems is an unprecedented event in the development of reactivity meters and only by this manner the reactivity can be precisely estimated in this regime. The present study is mainly addressed to fission reactors, and it could be employed in numerous experiments in research reactors. Therefore, this work has a theoretical and practical relevance, since it discusses a fundamental point of the nuclear reactor physics.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2018-02-05
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.