• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2013.tde-20012014-140902
Documento
Autor
Nombre completo
Tiago Cardoso Tardelli
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2013
Director
Tribunal
Yoriyaz, Hélio (Presidente)
Hormaza, Joel Mesa
Santos, Adimir dos
Título en portugués
Avaliação de dados nucleares para dosimetria de nêutrons
Palabras clave en portugués
dados nucleares
dose absorvida
Método de Monte Carlo
transporte de nêutron
Resumen en portugués
Doses absorvidas e doses efetivas podem ser calculadas utilizando códigos computacionais de transporte de radiação. A qualidade desses cálculos depende dos dados nucleares, no entanto, são raras as informações sobre as diferenças nas doses causadas por diferentes bibliotecas. O objetivo desse estudo é comparar os valores de dose (absorvida e efetiva) obtidos utilizando diferentes bibliotecas de dados nucleares devido a uma fonte externa de nêutrons na faixa de 10-11 a 20 MeV. As bibliotecas de dados nucleares são: JENDL 4.0, JEFF 3.1.1 e ENDF/B-VII.0. Cálculos de doses foram realizados utilizando o código MCNPX considerando o modelo antropomórfico da ICRP-110. As diferenças nos valores das doses absorvidas utilizando as bibliotecas JEFF 3.1.1 e a ENDF/B.VII são pequenas, em torno de 1%, porém os resultados obtidos com a JENDL 4.0 apresentam diferenças de até 85 % compara aos resultados da ENDF/B-VII.0 e JEFF 3.1.1. Diferenças nas doses efetivas são em torno de 1,5% entre ENDF/B-VII.0 e JEFF 3.1.1, e 11 % entre ENDF/B-VII.0 e JENDL 4.0.
Título en inglés
Evaluation of nuclear data for neutron dosimetry
Palabras clave en inglés
absorbed dose
Monte Carlo Method
neutron transport
nuclear data
Resumen en inglés
Absorbed dose and Effective dose are usually calculated using radiation transport computer codes. The quality of the calculations of absorbed dose depends on nuclear data utilized, however, there are rare information about the differences in dose caused by the use of different libraries. The objective of this study is to compare dose values obtained using different nuclear data libraries due to external source of neutrons in the energy range from 10-11 to 20 MeV. The nuclear data libraries used are: JENDL 4.0, JEFF 3.3.1 and ENDF/B.VII. Dose calculations were carried out with the MCNPX code considering the anthropomorphic ICRP 110 model. The differences in the absorbed dose values using JEFF 3.3.1 and ENDF/B.VII libraries are small, around 1%, but the results obtained with JENDL 4.0 presented differences up to 85% compared to ENDF and JEFF results. Differences in effective dose values are around 1.5% between ENDF and JEFF and 11% between ENDF/B.VII and JENDL 4.0.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-02-05
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.